Abstract
Reinforced concrete (RC) shear walls are frequently susceptible to construction-induced defects, such as localized basal holes, honeycombing, and reinforcement exposure. To ensure the structural integrity and seismic performance of these compromised components, this study proposed a targeted repair methodology utilizing Ultra-High-Performance Concrete (UHPC) and systematically evaluated its seismic performance. A comparative experiment was conducted, involving low-cycle reversed loading tests on both a UHPC-repaired specimen with localized defects and an intact specimen. Compared with the intact specimen, the repaired specimen exhibited significant enhancements in cumulative energy dissipation and ductility, increasing by 43.2% and 22.2%, respectively. At the same time, the hysteresis curve of the UHPC-repaired specimen became fuller, compared to the intact specimen. To further delineate the underlying seismic performance, a numerical parametric study was performed using the finite element method, investigating the sensitivities of repair area ratio, axial compression ratio and aspect ratios. The results demonstrated that the UHPC-repaired specimen exhibited seismic performance generally comparable to that of the intact specimen under the investigated conditions, providing a reliable solution for such construction defects.
Funding Information
  • National Natural Science Foundation of China (52478312)
  • Natural Science Foundation of Hunan Province (2025JJ70266)
  • Natural Science Foundation of Hunan Province (2025JJ70290)

This publication has 43 references indexed in Scilit: