Abstract
A multiple sprayer electrospray ion source for high‐throughput analysis is described. The ion source is comprised of multiple electrospray capillaries, each with an ion lens located near the tip. The electric potentials applied to the ion lenses are used to control the sprayers. The use of ion lenses eliminates the need for mechanical blocking devices to selectively enable or disable the sprayers, and results in a less expensive and more reliable set‐up. Sprayers can be enabled or disabled within approximately 50–250 ms when the lens potentials are controlled manually. For simultaneous operation of multiple electrospray capillaries, it is advantageous to orient the capillaries so that the spray from each passes directly in front of the entrance aperture of the mass spectrometer. Copyright © 2002 John Wiley & Sons, Ltd.Keywords
This publication has 29 references indexed in Scilit:
- An atmospheric pressure ion lens to improve electrospray ionization at low solution flow‐ratesRapid Communications in Mass Spectrometry, 2001
- Nanoflow Gradient Generator Coupled with μ-LC−ESI-MS/MS for Protein IdentificationAnalytical Chemistry, 2001
- Application of capillary electrophoresis-electrospray ionisation mass spectrometry to arsenic speciationJournal of Analytical Atomic Spectrometry, 1999
- Developments of a Fully Automated Parallel HPLC/Mass Spectrometry System for the Analytical Characterization and Preparative Purification of Combinatorial LibrariesAnalytical Chemistry, 1998
- Effect of multiple sprayers on dynamic range and flow rate limitations in electrospray and ionspray mass spectrometryRapid Communications in Mass Spectrometry, 1994
- Scale-up of electrospray atomization using linear arrays of Taylor conesReview of Scientific Instruments, 1993
- A new approach for the study of gas-phase ion-ion reactions using electrospray ionizationJournal of the American Society for Mass Spectrometry, 1992
- Evidence of charge inversion in the reaction of singly charged anions with multiply charged macroionsThe Journal of Physical Chemistry, 1991
- Ion spray interface for combined liquid chromatography/atmospheric pressure ionization mass spectrometryAnalytical Chemistry, 1987
- Electrospray interface for liquid chromatographs and mass spectrometersAnalytical Chemistry, 1985