Hybrid external fixation for neglected fractures of the distal radius: results after one year
Authors:
Open Access
- 19 September 2008
- journal article
- research article
- Published by Springer Nature in Journal of Orthopaedics and Traumatology
- Vol. 9 (4) , 195-200
Abstract
Background: External fixation is a well-established procedure for the treatment of unstable fractures of the distal radius, but its use is beset with complications. A plethora of theoretical and experimental data suggests that nonbridging fixators are superior for this setting. A new concept for the use of hybrid external fixation seemed reasonable and was applied for this study.Materials and methods: We report on the first 14 cases of unstable, extraarticular fractures of the distal radius with a one-year follow-up and describe the operative technique. All were treated at 3- weeks after injury; nevertheless, closed reduction after the fixator elements were fixed to the bone was always possible.Results: We had no intraoperative complications, but in the follow-up period three cases of algodystrophy and one transient irritation of the ulnar nerve ensued. One case developed superficial infection at the K-wire entry site that resolved with local care and systemic antibiotics. No redisplacements were observed. Early and late (at one year) evaluation of results revealed good and very good anatomic results (Lidström system) and two satisfactory (cases with algodystrophy), eight very good and four good functional outcomes (Gartland–Werley system). The patients-acceptance of the device was high.Conclusions: Hybrid external fixation of neglected distal radial fractures results in good outcomes if care is taken to prevent overdistraction of bone fragments.Keywords
This publication has 60 references indexed in Scilit:
- Hybrid external fixation of unstable distal radius fractures: initial experienceJournal of Orthopaedics and Traumatology, 2005
- Das akute CRPS I (Morbus Sudeck) nach distaler Radiusfraktur - Methoden der FrühdiagnostikZentralblatt fur Chirurgie, 2003
- Distal radius fractures: External fixation proves bestThe Journal of Hand Surgery, 1998
- Algodystrophy is an Early Complication of Colles’ FractureJournal of Hand Surgery (European Volume), 1997
- Closed Reduction and External Fixation of Unstable Fractures of the Distal RadiusScandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery, 1997
- Severe fractures of the distal radius: Effect of amount and duration of external fixator distraction on outcomeThe Journal of Hand Surgery, 1993
- The Surgical Treatment of Severe Comminuted Intraarticular Fractures of the Distal Radius With the Small AO External Fixation DeviceClinical Orthopaedics and Related Research, 1991
- Algodystrophy following Colles' fractureJournal of Hand Surgery (European Volume), 1989
- The Biologic Concept of Continuous Passive Motion of Synovial JointsClinical Orthopaedics and Related Research, 1989
- The Tension-Stress Effect on the Genesis and Growth of TissuesClinical Orthopaedics and Related Research, 1989