Abstract
This paper presents propagation of current sensor error through dq-transform and the propagated error effect on high-frequency injection (HFI) based self-sensing control. Three-phase AC systems use Clark and Park transform with a, b, c phase inputs for control purpose, i.e., dq-transform. When error exists in a, b, c inputs, e.g., due to quantization, gain, offset, noise, and others, the error propagates to d- and q-axes and dq-transform becomes inaccurate; therefore, the control performance degrades. Statistical models based on Variance are developed for 2- and 3- channel based dq-transform. The error Variance models are verified using error probability density function (PDF) with uniformly distributed random inputs. It is shown that the error propagated in dq-axes and self-sensing control performance become rotor position-dependent, following the error Variance model with error exists in current inputs. It is shown that error Variance of 2-channel based dq-transform becomes 3 times higher on average compared to 3-channel based dq-transform. It is demonstrated that 3-channel based self-sensing control results in lesser position estimation error compared to 2-channel based self-sensing with tradeoff in an additional sensor in machine drive system.

This publication has 27 references indexed in Scilit: