Comments on the NEMA NU 4-2008 Standard on Performance Measurement of Small Animal Positron Emission Tomographs
Preprint
Abstract
The National Electrical Manufacturers Association's (NEMA) NU 4-2008 standard specifies methodology for evaluating the performance of small-animal PET scanners. The standard's goal is to enable comparison of different PET scanners over a wide range of technologies and geometries used. In this work, we discuss if the NEMA standard meets these goals and we point out potential flaws and improvements to the standard. For the evaluation of spatial resolution, the NEMA standard mandates the use of filtered backprojection reconstruction. This reconstruction method can introduce star-like artifacts for detectors with an anisotropic spatial resolution, usually caused by parallax error. These artifacts can then cause a strong dependence of the resulting spatial resolution on the size of the projection window in image space, whose size is not fully specified in the NEMA standard. We show that the standard's equations for the estimation of the random rate for PET systems with intrinsic radioactivity are circular and not satisfiable. We compare random rates determined by a method based on the standard to to random rates obtained using a delayed coincidence window and two methods based on the singles rates. We discuss to what extend the NEMA standard's protocol for the evaluation of the sensitivity is unclear and ambiguous, which can lead to unclear interpretations of publicizeded results. The standard's definition of the recovery coefficients in the image quality phantom includes the maximum activity in a region of interest, which causes a positive correlation of noise and recovery coefficients. This leads to an unintended trade-off between desired uniformity, which is negatively correlated with variance (i.e. noise), and recovery. With this work, we want to start a discussion on possible improvements in a next version of the NEMA NU-4 standard.Keywords
All Related Versions
This publication has 23 references indexed in Scilit:
- Performance evaluation of the MOLECUBES β -CUBE—a high spatial resolution and high sensitivity small animal PET scanner utilizing monolithic LYSO scintillation detectorsPhysics in Medicine & Biology, 2018
- PET performance evaluation of MADPET4: a small animal PET insert for a 7 T MRI scannerPhysics in Medicine & Biology, 2017
- Performance evaluation of the small-animal PET scanner ClairvivoPET using NEMA NU 4-2008 StandardsPhysics in Medicine & Biology, 2015
- DigiPET: sub-millimeter spatial resolution small-animal PET imaging using thin monolithic scintillatorsPhysics in Medicine & Biology, 2014
- Quantitative PET and SPECT performance characteristics of the Albira Trimodal pre-clinical tomographPhysics in Medicine & Biology, 2014
- NEMA NU-4 performance evaluation of PETbox4, a high sensitivity dedicated PET preclinical tomographPhysics in Medicine & Biology, 2013
- NEMA NU-04-based performance characteristics of the LabPET-8™ small animal PET scannerPhysics in Medicine & Biology, 2011
- Improving the singles rate method for modeling accidental coincidences in high-resolution PETPhysics in Medicine & Biology, 2010
- Estimating accidental coincidences for pixelated PET detectors and singles list-mode acquisitionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006
- XXXI. Investigations in optics, with special reference to the spectroscopeJournal of Computers in Education, 1879