Magnetic Resonance Imaging at Ultrahigh Fields
Author:
- 1 May 2014
- journal article
- review article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 61 (5) , 1364-1379
Abstract
Since the introduction of 4 T human systems in three academic laboratories circa 1990, rapid progress in imaging and spectroscopy studies in humans at 4 T and animal model systems at 9.4 T have led to the introduction of 7 T and higher magnetic fields for human investigation at about the turn of the century. Work conducted on these platforms has demonstrated the existence of significant advantages in SNR and biological information content at these ultrahigh fields, as well as the presence of numerous challenges. Primary difference from lower fields is the deviation from the near field regime; at the frequencies corresponding to hydrogen resonance conditions at ultrahigh fields, the RF is characterized by attenuated traveling waves in the human body, which leads to image nonuniformities for a given sample-coil configuration because of interferences. These nonuniformities were considered detrimental to the progress of imaging at high field strengths. However, they are advantageous for parallel imaging for signal reception and parallel transmission, two critical technologies that account, to a large extend, for the success of ultrahigh fields. With these technologies, and improvements in instrumentation and imaging methods, ultrahigh fields have provided unprecedented gains in imaging of brain function and anatomy, and started to make inroads into investigation of the human torso and extremities. As extensive as they are, these gains still constitute a prelude to what is to come given the increasingly larger effort committed to ultrahigh field research and development of ever better instrumentation and techniques.Keywords
Funding Information
- NIH (P41 EB015894)
- NIH (1U54MH091657)
- NIH Blueprint for Neuroscience Research, and P30 NS076408
This publication has 203 references indexed in Scilit:
- 7 Tesla (T) human cardiovascular magnetic resonance imaging using FLASH and SSFP to assess cardiac function: validation against 1.5 T and 3 T.NMR in Biomedicine, 2011
- Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRIMagnetic Resonance in Medicine, 2010
- Magnetic field homogenization of the human prefrontal cortex with a set of localized electrical coilsMagnetic Resonance in Medicine, 2009
- In vivo 1H NMR spectroscopy of the human brain at high magnetic fields: Metabolite quantification at 4T vs. 7TMagnetic Resonance in Medicine, 2009
- Short echo spectroscopic imaging of the human brain at 7T using transceiver arraysMagnetic Resonance in Medicine, 2009
- Broadband slab selection with B mitigation at 7T via parallel spectral‐spatial excitationMagnetic Resonance in Medicine, 2009
- Initial results of cardiac imaging at 7 teslaMagnetic Resonance in Medicine, 2008
- Whole‐body imaging at 7T: Preliminary resultsMagnetic Resonance in Medicine, 2008
- Fast slice‐selective radio‐frequency excitation pulses for mitigating B inhomogeneity in the human brain at 7 TeslaMagnetic Resonance in Medicine, 2008
- Reduction of transmitter B1 inhomogeneity with transmit SENSE slice‐select pulsesMagnetic Resonance in Medicine, 2007