Efficiency and Thermal Changes during Implantoplasty in Relation to Bur Type
Authors:
- Eldad SharonESEldad Sharon
- Lior ShapiraLSLior Shapira
- Asaf WilenskyAWAsaf Wilensky
- Rami Abu‐HatoumRARami Abu‐Hatoum
- Ami SmidtASAmi Smidt
- 11 July 2011
- journal article
- research article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 15 (2) , 292-296
Abstract
Background: Implantoplasty is one of the options in treating peri‐implantitis. The efficacy of the dental bur used can reduce the time needed for the procedure and, as a consequence, minimize the risk of overheating that can negatively affect the remaining bone surrounding the implant.Purpose: The aim of this study was to evaluate the efficacy of three dental burs in removing implant substance (titanium) and to determine the amount of heat generated by each bur.Materials and Methods: Four burs with different surface properties (diamond, diamond – Premium Line, carbide, and smooth bur – control [Strauss Co., Raanana, Israel]) were attached to a high‐speed handpiece and applied to a titanium implant for a total of 60 seconds after cooling by water spray. Variations in temperature were recorded every 5 seconds, and the amount of implant substance removed (reduction in weight of the implant) was evaluated.Results: The diamond Premium Line bur removed 59.24 mg; carbide, 29.39 mg; diamond, 11.35 mg; and smooth bur (control) 0.19 mg, statistically significant. Only minimum thermal changes (∼1.5°C) were recorded for all four burs.Conclusions: There are considerable differences in efficiency of different burs working on titanium. Selecting the proper bur can reduce working time. Under proper cooling conditions, implantoplasty does not generate excess temperature increases that can damage soft tissue or bone surrounding the treated implant.Keywords
This publication has 18 references indexed in Scilit:
- Two‐year clinical results following treatment of peri‐implantitis lesions using a nanocrystalline hydroxyapatite or a natural bone mineral in combination with a collagen membraneJournal of Clinical Periodontology, 2007
- Surgical treatment of peri‐implantitis using a bone substitute with or without a resorbable membrane: a prospective cohort studyJournal of Clinical Periodontology, 2007
- Therapy of peri‐implantitis with resective surgery. A 3‐year clinical trial on rough screw‐shaped oral implants. Part II: radiographic outcomeClinical Oral Implants Research, 2006
- Prevalence and risk variables for peri‐implant disease in Brazilian subjectsJournal of Clinical Periodontology, 2006
- Healing of intrabony peri‐implantitis defects following application of a nanocrystalline hydroxyapatite (Ostim™) or a bovine‐derived xenograft (Bio‐Oss™) in combination with a collagen membrane (Bio‐Gide™). A case seriesJournal of Clinical Periodontology, 2006
- Nine‐ to fourteen‐year follow‐up of implant treatment. Part III: factors associated with peri‐implant lesionsJournal of Clinical Periodontology, 2006
- Therapy of peri‐implantitis with resective surgeryClinical Oral Implants Research, 2004
- Treatment of peri‐implant infections: a literature reviewJournal of Clinical Periodontology, 2003
- Long‐term implant prognosis in patients with and without a history of chronic periodontitis: a 10‐year prospective cohort study of the ITI® Dental Implant SystemClinical Oral Implants Research, 2003
- Heat shock‐induced necrosis and apoptosis in osteoblastsJournal of Orthopaedic Research, 1999