Performance of the matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for rapid identification of streptococci: a review
Authors:
- 23 January 2017
- journal article
- research article
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 36 (6) , 1005-1012
Abstract
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been developed as a new type of soft ionization mass spectrometry in recent years. An increasing number of clinical microbiological laboratories consider it as an innovative approach for bacterial identification. This study was undertaken in order to evaluate the use of MALDI-TOF MS for rapid identification of the clinical streptococci. A systematic review was conducted based on a literature search of the Medline and Embase databases. Fixed-effects models based on the P-value and the I-square were used for meta-analysis while considering the possibility of heterogeneity between studies. Statistical analyses were performed by using STATA 11.0. Twenty-seven studies covering 3,540 streptococci were included in our meta-analysis. The MALDI-TOF MS correctly identified the species of 96% (I2 = 92.8, P < 0.1) of the streptococci. The MALDI-TOF MS correctly identified the species of 99% of the Streptococcus pneumoniae (I2 = 85.2%, P < 0.1), 100% of the Streptococcus pyogenes (I2 = 32.8%, P > 0.1), and 100% of Streptococcus agalactiae (I2 = 20.7%, P > 0.2). What’s more, it also had high confidence in other Streptococcus. But the accuracy of bovis needs to be improved. The overall performance of both MALDI-MS systems was different. Notably, the identifying accuracy rate of streptococci by VITEK MS was 98%, compared to 94% by the MALDI biotyper system. Interestingly, when analyzing the incorrect identification of MALDI-TOF MS, 36 out of the 38 strains of Streptococcus mitis/oralis were inaccurately identified as Streptococcus pneumoniae by the MALDI biotyper system. In conclusion, the results of this review indicated that MALDI-TOF MS could be a reliable and rapid method for identification of the streptococci.Keywords
Funding Information
- The Chinese National Natural Science Foundation (81471994)
- Natural Science Foundation of Jiangsu Province (BK20151154)
- a youth science and technology innovation team project of Xuzhou Medical University
This publication has 49 references indexed in Scilit:
- Identification of Clinical Isolates of α-Hemolytic Streptococci by 16S rRNA Gene Sequencing, Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Using MALDI Biotyper, and Conventional Phenotypic Methods: a ComparisonJournal of Clinical Microbiology, 2012
- Performances of the Vitek MS Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry System for Rapid Identification of Bacteria in Routine Clinical MicrobiologyJournal of Clinical Microbiology, 2012
- Comparison of the Microflex LT and Vitek MS Systems for Routine Identification of Bacteria by Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass SpectrometryJournal of Clinical Microbiology, 2012
- Phoenix 100 versus Vitek 2 in the Identification of Gram-Positive and Gram-Negative Bacteria: a Comprehensive Meta-AnalysisJournal of Clinical Microbiology, 2011
- Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Rapid Identification of Beta-Hemolytic StreptococciJournal of Clinical Microbiology, 2011
- Comparison of Two Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Methods with Conventional Phenotypic Identification for Routine Identification of Bacteria to the Species LevelJournal of Clinical Microbiology, 2010
- High-Throughput Identification of Bacteria and Yeast by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry in Conventional Medical Microbiology LaboratoriesJournal of Clinical Microbiology, 2010
- Direct Identification of Bacteria in Positive Blood Culture Bottles by Matrix-Assisted Laser Desorption Ionisation Time-of-Flight Mass SpectrometryPLOS ONE, 2009
- Rapid Identification of Viridans Streptococci by Mass Spectrometric DiscriminationJournal of Clinical Microbiology, 2007
- Characterization of intact microorganisms by MALDI mass spectrometryMass Spectrometry Reviews, 2001