Maxillary sinus augmentation using computer‐aided design/computer‐aided manufacturing (CAD/CAM) technology
- 7 September 2012
- journal article
- research article
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 9 (3) , 331-338
Abstract
Background: Maxillary sinus augmentation is a common method for increasing bone height for insertion of dental implants. In most cases, the graft is manually cut into a roughly appropriate shape by visual estimation during the operation; accordingly, the shape of the graft depends considerably on the experience of the surgeon. We have developed a computer‐aided design/computer‐aided manufacturing (CAD/CAM) technique to generate custom‐made block grafts for sinus augmentation, and a customized cutting guide to precisely position the lateral wall and facilitate membrane elevation, using cone‐beam computed tomography (CBCT).Methods: Custom‐made blocks of hydroxyapatite (HA) were preoperatively cut to the required shape, based on a three‐dimensional (3D) simulation, using CAD/CAM technology. The custom‐made HA blocks were used for sinus augmentation.Results: Five patients underwent bilateral sinus elevation with custom‐made HA blocks. Six months later, implants were placed. Two years after placement, all implants were in function. No clinical or prosthetic complications were encountered.Conclusions: We present a CAD/CAM technique for the fabrication of custom‐made block grafts for sinus augmentation.Copyright © 2012 John Wiley & Sons, Ltd.Keywords
This publication has 18 references indexed in Scilit:
- Clinical Evaluation of Demineralized Bone Allograft for Sinus Lifts in Humans: A Clinical and Histologic StudyImplant Dentistry, 2011
- Sinus Pathology and Anatomy in Relation to Complications in Lateral Window Sinus AugmentationImplant Dentistry, 2011
- Prospective clinical evaluation of 201 direct laser metal forming implants: results from a 1-year multicenter studyLasers in Medical Science, 2011
- Location of posterior superior alveolar artery and evaluation of maxillary sinus anatomy with computerized tomography: a clinical studyClinical Oral Implants Research, 2011
- Corrective osteotomy using customized hydroxyapatite implants prepared by preoperative computer simulationThe International Journal of Medical Robotics and Computer Assisted Surgery, 2010
- Application of computer‐aided three‐dimensional skull model with rapid prototyping technique in repair of zygomatico‐orbito‐maxillary complex fractureThe International Journal of Medical Robotics and Computer Assisted Surgery, 2009
- Implant Success, Survival, and Failure: The International Congress of Oral Implantologists (ICOI) Pisa Consensus ConferenceImplant Dentistry, 2008
- A Literature Review on Biomaterials in Sinus Augmentation ProceduresClinical Implant Dentistry and Related Research, 2007
- Computed tomography‐based tissue‐engineered scaffolds in craniomaxillofacial surgeryThe International Journal of Medical Robotics and Computer Assisted Surgery, 2007
- Tridimensional Analysis of Maxillary Sinus Anatomy Related to Sinus Lift ProcedureImplant Dentistry, 2006