Development and Temporal Validation of a Nomogram to Predict Actionable Arrhythmias During Implantable Cardiac Monitoring in Patients with Unexplained Syncope
Open Access
- 14 November 2026
- journal article
- research article
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 13 (11) , 595
Abstract
Prediction tools for actionable arrhythmias after implantable cardiac monitor (ICM) implantation in patients with unexplained syncope remain limited. This dual-center retrospective study included 302 patients divided chronologically into development (n = 91) and temporal validation (n = 211) cohorts. The endpoint was the first ICM-detected arrhythmia prompting permanent pacemaker or defibrillator implantation, catheter ablation, initiation of Vaughan Williams Class I or III antiarrhythmic drugs, or oral anticoagulation. A multivariable Cox model was developed and internally validated using 1000 bootstrap resamples, repeating variable selection and model fitting. During a median follow-up of 23.4 months, 78 patients reached the endpoint, including 32 in the development cohort and 46 in the temporal validation cohort. The nomogram included age, a history of recurrent syncope, and first-degree atrioventricular block. The optimism-corrected C-index was 0.720 in development. In temporal validation, the C-index was 0.707 (95% confidence interval, 0.623–0.790), and the 12- and 24-month time-dependent areas under the receiver operating characteristic curve were 0.733 and 0.741, respectively. The nomogram showed moderate discrimination in temporal validation at the same two centers. The model underestimated risk at 12 months, whereas mean predicted risk was closer to observed risk at 24 months.Keywords
Funding Information
- Beijing Municipal Science and Technology Commission, Adminitrative Commission of Zhongguancun Science Park (Z241100009024029)
- National High Level Hospital Clinical Research Funding (BJ-2025-157)
This publication has 34 references indexed in Scilit:
- Prevalence of clinically significant bradyarrhythmias in patients implanted with loop recorders for cryptogenic stroke: A manifestation of atrial cardiomyopathy?Heart Rhythm, 2026
- Predictors of pacemaker requirement in patients receiving implantable loop recorders for unexplained syncope: A systematic review and meta-analysisHeart Rhythm, 2024
- Predictors of pacemaker requirement in patients with implantable loop recorder and unexplained syncope: A systematic review and meta‐analysisClinical Cardiology, 2024
- Clinical Predictors of Pacing Device Implantation in Implantable Cardiac Monitor Recipients for Unexplained SyncopeCJC Open, 2022
- Current and Future Use of Insertable Cardiac MonitorsJACC: Clinical Electrophysiology, 2018
- “First-degree AV block—a benign entity?” Insertable cardiac monitor in patients with 1st-degree AV block reveals presence or progression to higher grade block or bradycardia requiring pacemaker implantJournal of Interventional Cardiac Electrophysiology, 2018
- Implantable loop recorders in the real world: a study of two Canadian centersJournal of Interventional Cardiac Electrophysiology, 2017
- The diagnostic yield of implantable loop recorders in unexplained syncope: A systematic review and meta-analysisInternational Journal of Cardiology, 2017
- Predictive factors for pacemaker implantation in patients receiving an implantable loop recorder for syncope remained unexplained after an extensive cardiac and neurological workupInternational Journal of Cardiology, 2013
- Long-term Outcomes in Individuals With Prolonged PR Interval or First-Degree Atrioventricular BlockJAMA, 2009