MRI of perfluorocarbon emulsion kinetics in rodent mammary tumours
Authors:
- Jonathan N RiverJRJonathan N River
- Adrian S MuresanAMAdrian S Muresan
- Carmen PopescuCPCarmen Popescu
- Marta ZamoraMZMarta Zamora
- Rita M CulpRCRita M Culp
- Gregory S KarczmarGKGregory S Karczmar
- 21 December 2005
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (2) , 211-220
Abstract
Perfluorocarbon (PFC) emulsions can be imaged directly by fluorine-19 MRI. We developed an optimized protocol for preparing PFC droplets of uniform size, evaluated use of the resulting droplets as blood pool contrast agents, studied their uptake by tumours and determined the spatial resolution with which they can be imaged at 4.7 T. Perfluorocarbon droplets of three different average sizes (324, 293 and 225 nm) were prepared using a microemulsifier. Images of PFC droplets with good signal-to-noise ratio were acquired with 625 microm in-plane resolution, 3 mm slice thickness and acquisition time of approximately 4.5 min per image. Kinetics of washout were determined using a simple mathematical model. The maximum uptake of the PFC droplets was three times greater at the tumour rim than in muscle, but the washout rate was two to three times slower in the tumour. The results are consistent with leakage of the droplets into the tumour extravascular space due to the hyper-permeability of tumour capillaries. PFC droplets may allow practical and quantitative measurements of blood volume and capillary permeability in tumours with reasonable spatial resolution.Keywords
This publication has 21 references indexed in Scilit:
- MRI detection of tumor in mouse lung using partial liquid ventilation with a perfluorocarbon-in-water emulsionMagnetic Resonance Imaging, 2004
- New model for analysis of dynamic contrast‐enhanced MRI data distinguishes metastatic from nonmetastatic transplanted rodent prostate tumorsMagnetic Resonance in Medicine, 2004
- Effect of carbogen on tumor oxygenation: combined fluorine-19 and proton MRI measurementsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2002
- Regional tumor oxygen dynamics: 19F PBSR EPI of hexafluorobenzeneMagnetic Resonance Imaging, 1997
- Water diffusion and exchange as they influence contrast enhancementJournal of Magnetic Resonance Imaging, 1997
- Rapid tissue oxygen tension mapping using 19F inversion‐recovery echo‐planar imaging of P erfluoro‐15 ‐crown‐5‐etherMagnetic Resonance in Medicine, 1994
- In situ assessment of tumor vascularity using fluorine nmr imagingMagnetic Resonance in Medicine, 1990
- 19F NMR imaging of blood oxygenation in the brainMagnetic Resonance in Medicine, 1988
- Perfluorinated Organic Liquids and Emulsions as Biocompatible NMR Imaging Agents for 19F and Dissolved Oxygen1984
- Survival of Mammals Breathing Organic Liquids Equilibrated with Oxygen at Atmospheric PressureScience, 1966