Reduction of influence of variation in center frequencies of RF echoes on estimation of artery-wall strain
- 19 September 2008
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 55 (9) , 1921-1934
Abstract
Atherosclerotic change of the arterial wall leads to a significant change in its elasticity. For assessment of elasticity, measurement of arterial wall deformation is required. For motion estimation, correlation techniques are widely used, and we have developed a phase-sensitive correlation method, namely, the phased-tracking method, to measure the regional strain of the arterial wall due to the heartbeat. Although phase-sensitive methods using demodulated complex signals require less computation in comparison with methods using the correlation between RF signals or iterative methods, the displacement estimated by such phase-sensitive methods are biased when the center frequency of the RF echo apparently varies. One of the reasons for the apparent change in the center frequency would be the interference of echoes from scatterers within the wall. In the present study, a method was introduced to reduce the influence of variation in the center frequencies of RF echoes on the estimation of the artery-wall strain when using the phase-sensitive correlation technique. The improvement in the strain estimation by the proposed method was validated using a phantom. The error from the theoretical strain profile and the standard deviation in strain estimated by the proposed method were 12.0% and 14.1%, respectively, significantly smaller than those (23.7% and 46.2%) obtained by the conventional phase-sensitive correlation method. Furthermore, in the preliminary in vitro experimental results, the strain distribution of the arterial wall well corresponded with pathology, i.e., the region with calcified tissue showed very small strain, and the region almost homogeneously composed of smooth muscle and collagen showed relatively larger strain and clear strain decay with respect to the radial distance from the lumen.Keywords
This publication has 48 references indexed in Scilit:
- Tissue Classification of Arterial Wall Based on Elasticity ImageJapanese Journal of Applied Physics, 2006
- Construction of Reference Data for Tissue Characterization of Arterial Wall Based on Elasticity ImagesJapanese Journal of Applied Physics, 2005
- Evaluating the regional elastic modulus of a cylindrical shell with nonuniform wall thicknessJournal of Medical Ultrasonics, 2004
- Spectral estimators in elastographyUltrasonics, 2000
- Power spectral strain estimators in elastographyUltrasound in Medicine & Biology, 1999
- Deformation models and correlation analysis in elastographyThe Journal of the Acoustical Society of America, 1996
- Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique1985
- Comparison of the deskewed short-time correlator and the maximum likelihood correlatorIEEE Transactions on Acoustics, Speech, and Signal Processing, 1984
- Estimation of location and motion parameters of a moving source observed from a linear arrayThe Journal of the Acoustical Society of America, 1981
- Correlator compensation requirements for passive time-delay estimation with moving source or receiversIEEE Transactions on Acoustics, Speech, and Signal Processing, 1980