This paper investigates the technical performance of 230 kV field-aged composite insulators in the coastal region of Saudi Arabia. Two insulator samples removed from the 230 kV line after 20 years of service are assessed at KFUPM High Voltage Lab (KHVL). Different assessment techniques, such as visual inspection, contact angle, surface pollution severity, electrical withstand, and material characterization are utilized to evaluate the insulator performance. Equivalent salt deposit density (ESDD) and non-soluble deposit density (NSDD) techniques are used for the surface pollution severity measurements. Clear views of surface changes and surface hydrophobicity conditions are displayed. Scanning electron microscope (SEM), energy dispersive x-ray spectrometry (EDX), and Fourier-transform infrared spectroscopy (FTIR-IR) techniques are utilized for the material characterization. The visual inspection reveals small and big cracks in the insulator sheds. Hard breakable portion areas, many shed cuts, changed color areas, and whitish parts are visually noticed in the insulator surface. Such changes confirm the aging condition effect of the insulator units. Furthermore, the samples are subjected to laboratory clean fog tests to check the electrical performance of the samples. Informative results are given for the current condition and performance for the 20-years, field-aged insulators. Additionally, the experimental results are presented for the rest of the insulator life period. Utilization of the existing line insulators has been evaluated. Finally, discussions and recommendations for the future handling of the insulators at the 230 kV line are highlighted.Keywords
Funding Information
- Center for Engineering Research, Research Institute, King Fahd University of Petroleum and Minerals (KFUPM), Saudi Arabia
This publication has 25 references indexed in Scilit:
- Prediction of the Levels of Contamination of HV Insulators Using Image Linear Algebraic Features and Neural NetworksArabian Journal for Science and Engineering, 2015
- Aging characterization of high temperature vulcanized silicone rubber housing material used for outdoor insulationIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Laboratory investigation on hydrophobicity and tracking performance of field aged composite insulators2014
- Leakage current characterization for estimating the conditions of non-ceramic insulators’ surfacesElectric Power Systems Research, 2007
- Characterization of field-aged 400 kV silicone rubber composite insulators2006
- Leakage current characterization for estimating the conditions of ceramic and polymeric insulating surfacesIEEE Transactions on Dielectrics and Electrical Insulation, 2004
- History and bibliography of polymeric insulators for outdoor applicationsIEEE Transactions on Power Delivery, 1993
- Aging in silicone rubber used for outdoor insulationIEEE Transactions on Power Delivery, 1992
- Experience from insulators with RTV silicon rubber sheds and shed coatingsIEEE Transactions on Power Delivery, 1990
- The electrical performance of polymeric insulating materials under accelerated aging in a fog chamberIEEE Transactions on Power Delivery, 1988