Sealing SU-8 microfluidic channels using PDMS
Authors:
- 9 November 2011
- journal article
- conference paper
- Published by AIP Publishing in Biomicrofluidics
- Vol. 5 (4) , 046503-465038
Abstract
A simple method of irreversibly sealing SU-8 microfluidic channels using PDMS is reported in this paper. The method is based on inducing a chemical reaction between PDMS and SU-8 by first generating amino groups on PDMS surface using N2 plasma treatment, then allowing the amino groups to react with the residual epoxy groups on SU-8 surface at an elevated temperature. The N2 plasma treatment of PDMS can be conducted using an ordinary plasma chamber and high purity N2, while the residual epoxy groups on SU-8 surface can be preserved by post-exposure baking SU-8 at a temperature no higher than 95 °C. The resultant chemical bonding between PDMS and SU-8 using the method create an interface that can withstand a stress that is greater than the bulk strength of PDMS. The bond is permanent and is long-term resistant to water. The method was applied in fabricating SU-8 microfluidi-photonic integrated devices, and the obtained devices were tested to show desirable performance.Keywords
This publication has 15 references indexed in Scilit:
- Formation and characterization of an ideal excitation beam geometry in an optofluidic deviceBiomedical Optics Express, 2010
- A novel single-use SU-8 microvalve for pressure-driven microfluidic applicationsJournal of Micromechanics and Microengineering, 2009
- Fabrication of SU-8 based microchip electrophoresis with integrated electrochemical detection for neurotransmittersTalanta, 2009
- Characterization of a microfluidic magnetic bead separator for high-throughput applicationsSensors and Actuators A: Physical, 2008
- Self-assembled epoxy-modified polymer coating on a poly(dimethylsiloxane) microchip for EOF inhibition and biopolymers separationLab on a Chip, 2007
- Generation of Hydrophilic Poly(dimethylsiloxane) for High-Performance Microchip ElectrophoresisAnalytical Chemistry, 2006
- Micropositioning and microscopic observation of individual picoliter-sized containers within SU-8 microchannelsMicrofluidics and Nanofluidics, 2006
- A SU-8/PDMS Hybrid Microfluidic Device with Integrated Optical Fibers for Online Monitoring of LactateBiomedical Microdevices, 2005
- Measurements of scattered light on a microchip flow cytometer with integrated polymer based optical elementsLab on a Chip, 2004
- PMMA to SU-8 bonding for polymer based lab-on-a-chip systems with integrated opticsJournal of Micromechanics and Microengineering, 2004