Evaluation of Risk Factors for Luxation After Total Hip Replacement in Dogs
Authors:
- Erik R. WisnerEWErik R. Wisner
- Marvin L. OlmsteadMOMarvin L. Olmstead
- 1 November 2000
- journal article
- Published by Wiley in Veterinary Surgery
- Vol. 29 (6) , 524-532
Abstract
Objective—To identify risk factors for luxation after canine total hip replacement (THR).Study design—Retrospective study.Sample population—256 client‐owned dogs that underwent THR.Methods—Patient data surveyed included signalment, body weight, diagnosis, prior hip surgery, implant size, intraoperative complications, and angle of lateral opening of the acetabular component.Results—Postoperative complications were recorded in 20 cases (7.8%). The most common complication was dorsal luxation which occurred in 12 dogs (4.7%). The interval between joint replacement and luxation ranged from 1 to 116 days (mean, 44 days). In 1 case, luxation was attributable to failure of the repair of an intraoperative fracture of the greater trochanter. Excluding this case, the mean angle of lateral opening in those dogs that sustained luxation was 62° (range, 46°‐75°). The mean angle of lateral opening overall was 48° (range, 18°‐76°). The angle of lateral opening was the only factor that had a statistically significant effect on whether luxation occurred (P= .035). Acetabular revision, performed primarily to reduce the angle of lateral opening, was performed in 8 dogs and successfully prevented subsequent luxation.Conclusion—Luxation of the prosthesis is substantially under the control of the surgeon. It is recommended that the acetabular cup be inserted at an angle of lateral opening of 35° to 45°. In those cases of THR luxation in which an inappropriate angle of lateral opening is identified, acetabular revision arthroplasty generally results in a good clinical outcome.Keywords
This publication has 11 references indexed in Scilit:
- Computer Assisted Measurement of Cup Placement in Total Hip ReplacementClinical Orthopaedics and Related Research, 1998
- The Influence of Patient-Related Factors and the Position of the Acetabular Component on the Rate of Dislocation after Total Hip Replacement*Journal of Bone and Joint Surgery, 1997
- The Prognosis and Treatment of Dislocated Total Hip Arthroplasties with a 22MM HeadThe Journal of Bone and Joint Surgery. British volume, 1997
- Outcome and Long-Term Results Following Total Hip Replacement in Elderly PatientsClinical Orthopaedics and Related Research, 1995
- The canine cemented modular total hip prosthesisJournal of the American Animal Hospital Association, 1995
- Causes of dislocation of total hip arthroplasty. CT study of component alignmentThe Journal of Bone and Joint Surgery. British volume, 1994
- Total Hip ReplacementVeterinary Clinics of North America: Small Animal Practice, 1987
- RADIOGRAPHIC EVALUATION OF TOTAL HIP REPLACEMENT IN THE DOGVeterinary Radiology, 1982
- Dislocation following total hip replacementThe Journal of Bone and Joint Surgery. British volume, 1981
- Dislocations after total hip-replacement arthroplasties.Journal of Bone and Joint Surgery, 1978