Mechanical Stability of Thoracolumbar Pedicle Screw Fixation
Authors:
- Debi P. MukherjeeDMDebi P. Mukherjee
- Robert N. KruseRKRobert N. Kruse
- Kalia K. SadasivanKSKalia K. Sadasivan
- James A. AlbrightJAJames A. Albright
- 1 July 1997
- journal article
- Published by Wolters Kluwer Health in Spine
- Vol. 22 (14) , 1568-1572
Abstract
Pedicle screw fixation for unstable thoracolumbar spine injuries is relatively new. The effect of one or two crosslinks on rotational and lateral bending stiffness was studied. To determine the rotational and bending stiffness values of thoracolumbar fractures fixed by the AO's internal fixation system with zero, one, or two crosslinks. Eight embalmed thoracolumbar spine segments. (T12-L2) were instrumented at T12 and L2 with a pedicle screw-rod system. Rotational stiffness was determined for 10 cycles to 2.5 degrees, 3.5 degrees, and 5 degrees of rotation, with and without one or two crosslinks, and lateral bending stiffness for 10 cycles to 0.25, 0.40, and 0.50 inch. The results showed a clear trend toward increased stiffness with crosslinks. The stiffness values of the two-crosslink construct at 2.5 degrees and 3.5 degrees of rotation were significantly higher than those of the zero-crosslink system. Also, the bending stiffness of the two-crosslink construct was significantly higher than that of no-crosslink system at all of the displacements. Rotational stiffness values of the two-crosslink construct were significantly higher than those of the zero-crosslink system, at 2.5 degrees and 3.5 degrees of rotation. Lateral bending stiffness of the two-crosslink system was higher than that of the zero-crosslink system at all levels of displacement.Keywords
This publication has 14 references indexed in Scilit:
- Anatomic and Biomechanical Study of Posterior Cervical Spine Plate ArthrodesisJournal of Spinal Disorders, 1992
- Mechanical Stability of the Pedicle Screw Fixation Systems for the Lumbar SpineSpine, 1992
- A New Instrumentation System for the Reduction and Posterior Stabilization of Unstable Thoracolumbar FracturesNeurosurgery, 1992
- Biomechanics of Spinal Fixation and FusionSpine, 1991
- Operative Treatment of Spinal Fractures with the AO Internal FixatorSpine, 1991
- The Fixateur Interne in the Reduction and Stabilization of Thoracolumbar Spine Fractures in Patients with Neurologic DeficitSpine, 1991
- Internal Forces and Moments in Transpedicular Spine Instrumentation The Effect of Pedicle Screw Angle and Transfixation— The 4R-4Bar Linkage ConceptSpine, 1990
- A Biomechanical Investigation of Short Segment Spinal Fixation for Burst Fractures with Varying Degrees of Posterior DisruptionSpine, 1990
- The “Fixatuer Interne” as a Versatile Implant for Spine SurgerySpine, 1987
- Cyclic Axial Loading of Spinal ImplantsSpine, 1985