Full-Coverage Film Cooling: Film Effectiveness and Heat Transfer Coefficients for Dense Hole Arrays at Different Hole Angles, Contraction Ratios, and Blowing Ratios
- 14 February 2013
- journal article
- Published by Wiley in Journal of Heat Transfer
- Vol. 135 (3) , 031707
Abstract
Experimental results are presented for a full-coverage film cooling arrangement which simulates a portion of a gas turbine engine, with appropriate streamwise static pressure gradient. The test surface utilizes varying blowing ratio (BR) along the length of the contraction passage which contains the cooling hole arrangement. For the different experimental conditions examined, film cooling holes are sharp-edged and streamwise inclined either at 20 deg or 30 deg with respect to the liner surface. The film cooling holes in adjacent streamwise rows are staggered with respect to each other. Data are provided for turbulent film cooling, contraction ratios of 1, 3, 4, and 5, blowing ratios (at the test section entrance) of 2.0, 5.0, and 10.0, coolant Reynolds numbers Refc of 10,000–12,000, freestream temperatures from 75 °C to 115 °C, a film hole diameter of 7 mm, and density ratios from 1.15 to 1.25. Nondimensional streamwise and spanwise film cooling hole spacings, X/D and Y/D, are 6, and 5, respectively. When the streamwise hole inclination angle is 20 deg spatially averaged and line-averaged adiabatic effectiveness values at each x/D location are about the same as the contraction ratio varies between 1, 3, and 4, with slightly higher values at each x/D location when the contraction ratio Cr is 5. For each contraction ratio, there is a slight increase in effectiveness when the blowing ratio is increased from 2.0 to 5.0 but there is no further substantial improvement when the blowing ratio is increased to 10.0. Overall, line-averaged and spatially averaged-adiabatic film effectiveness data, and spatially averaged heat transfer coefficient data are described as they are affected by contraction ratio, blowing ratio, hole angle α, and streamwise location x/D. For example, when α = 20 deg, the detrimental effects of mainstream acceleration are apparent since heat transfer coefficients for contraction ratios Cr of 3 and 5 are often higher than values for Cr = 1, especially for x/D > 100.Keywords
This publication has 19 references indexed in Scilit:
- Full-Coverage Film Cooling: Film Effectiveness and Heat Transfer Coefficients for Dense and Sparse Hole Arrays at Different Blowing RatiosJournal of Turbomachinery, 2012
- Investigation of Velocity Profiles for Effusion Cooling of a Combustor LinerJournal of Turbomachinery, 2006
- Effect of Unheated Starting Lengths on Film Cooling ExperimentsJournal of Turbomachinery, 2006
- Film cooling characteristics of rows of round holes at various streamwise angles in a crossflow: Part I. EffectivenessInternational Journal of Heat and Mass Transfer, 2005
- Interaction of Film Cooling Rows: Effects of Hole Geometry and Row Spacing on the Cooling Performance Downstream of the Second Row of HolesJournal of Turbomachinery, 2004
- Transonic Film Cooling Effectiveness from Shaped Holes on a Simulated Turbine AirfoilJournal of Thermophysics and Heat Transfer, 2002
- Film Cooling From Shaped HolesJournal of Heat Transfer, 1999
- High-Resolution Measurements of Local Heat Transfer Coefficients From Discrete Hole Film CoolingJournal of Turbomachinery, 1999
- High-Resolution Measurements of Local Effectiveness From Discrete Hole Film CoolingJournal of Turbomachinery, 1999
- Film Cooling Effectiveness for Injection from Multirow HolesJournal of Engineering for Power, 1979