Emergency Medical Services Responses to 9-1-1 Calls Triggered by Personal Emergency Response Systems
Authors:
- 31 July 2025
- journal article
- Published by Taylor & Francis in Prehospital Emergency Care
- p. 1-7
Abstract
Many elderly adults utilize wearable personal emergency response systems (PERS) to support independent living while ensuring prompt assistance in an emergency. Activation of emergency medical services (EMS) is integral to the PERS model, but the impact of PERS activation on the utilization of EMS is not well described. We examined EMS responses to 9-1-1 calls related to PERS activations in a large EMS system over a ten-year period and evaluated the appropriateness of lights and siren (L&S) response. This retrospective analysis included 9-1-1 responses to PERS activations by a single agency between January 1, 2013, and December 31, 2022. Descriptive statistics were used to summarize the chief complaint assigned by the emergency medical dispatcher (EMD), response mode, and transport mode. Logistic regression was used to assess the association between EMD-assigned final chief complaint and L&S patient transport. Duration of L&S response (minutes) was computed as the interval between time unit dispatched and either unit arrival (patient contact), or unit cancellation (no patient contact). Activations related to PERS (n = 18,660) comprised 2.5% of all 9-1-1 calls involving adult patients. Lights and siren were used in 96% of PERS responses, and patient contact, patient transport, and L&S transport occurred in 36%, 25%, and 1.4%, respectively. Patients evaluated by EMS were most often female (72%) and ages 85+ (39%). Dispatcher modification of the chief complaint from PERS alarm to a more clinically specific complaint code was univariately associated with an increased odds of L&S transport (OR = 2.85, CI = 2.10-3.87). Between 2013 and 2022, responses to PERS activations accounted for 1,734 hours of L&S use, of which 1,087 hours (63%) were attributable to calls cancelled prior to patient contact. A significant proportion of PERS responses in this system are cancelled prior to patient contact or involve low acuity patients, and L&S patient transport is rare. Dispatcher determination of the specific nature of the problem increases the likelihood of the need for L&S transport after PERS activations. These findings provide a strong rationale for EMS systems transitioning away from the use of L&S response to PERS calls in the absence of definitive situational information.Keywords
This publication has 12 references indexed in Scilit:
- Ambulance deployment without transport: a retrospective difference analysis for the description of emergency interventions without patient transport in BavariaScandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 2023
- Joint Statement on Lights & Siren Vehicle Operations on Emergency Medical Services ResponsesPrehospital Emergency Care, 2022
- Exploring patterns of personal alarm system use and impacts on outcomesAustralasian Journal on Ageing, 2021
- Using Red Lights and Sirens for Emergency Ambulance Response: How Often Are Potentially Life-Saving Interventions Performed?Prehospital Emergency Care, 2020
- Predictive Modeling of 30-Day Emergency Hospital Transport of Patients Using a Personal Emergency Response System: Prognostic Retrospective StudyJMIR Medical Informatics, 2018
- Ten years of EMS Fall Calls in a Community: An Opportunity for Injury Prevention StrategiesGeriatric Orthopaedic Surgery & Rehabilitation, 2018
- Healthcare utilization in older patients using personal emergency response systems: an analysis of electronic health records and medical alert dataBMC Health Services Research, 2017
- The Personal Emergency Response System as a Technology Innovation in Primary Health Care Services: An Integrative ReviewJournal of Medical Internet Research, 2016
- Emergency medical dispatchEmergency Medicine Clinics of North America, 2002
- Personal Emergency Response SystemsJournal of Burn Care & Rehabilitation, 1992