First-in-human clinical series of a novel conformable large-lattice pulsed field ablation catheter for pulmonary vein isolation
Open Access
- 30 March 2024
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (4)
Abstract
Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5–6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan–Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2–89.2%) for the total, and 100% (95% CI 80.6–100%) for the PULSE3 cohort. Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.Keywords
Funding Information
- Affera, Inc
This publication has 41 references indexed in Scilit:
- Pulsed Field Ablation in Patients With Persistent Atrial FibrillationJACC, 2020
- Ostial dimensional changes after pulmonary vein isolation: Pulsed field ablation vs radiofrequency ablationHeart Rhythm, 2020
- Pulsed Field Ablation Using a Lattice Electrode for Focal Energy DeliveryCirculation: Arrhythmia and Electrophysiology, 2020
- Focal Pulsed Field Ablation for Pulmonary Vein Isolation and Linear Atrial LesionsCirculation: Arrhythmia and Electrophysiology, 2020
- Pulsed Field Ablation Versus Radiofrequency AblationCirculation: Arrhythmia and Electrophysiology, 2020
- Preclinical Evaluation of Pulsed Field AblationCirculation: Arrhythmia and Electrophysiology, 2019
- Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial FibrillationJACC, 2019
- Acute and Long-Term Effects of Full-Power Electroporation Ablation Directly on the Porcine EsophagusCirculation: Arrhythmia and Electrophysiology, 2017
- Silent Cerebral Events/Lesions Related to Atrial Fibrillation Ablation: A Clinical ReviewJournal of Cardiovascular Electrophysiology, 2015
- Autonomic Denervation Added to Pulmonary Vein Isolation for Paroxysmal Atrial FibrillationJACC, 2013