Fluorophotometric measurements of tear turnover rate in normal healthy persons: Evidence for a circadian rhythm
Authors:
- 1 September 1987
- journal article
- research article
- Published by Springer Nature in Eye
- Vol. 1 (5) , 615-620
Abstract
The determination of tear turnover rate in a total of 16 normal healthy volunteers is described. A continuous reading fluorophotometer is used to measure the fluorescence resulting from the instillation of 1 µl of 2 per cent fluorescein into the eye. A mean (± s.d.) turnover rate of 14.9 ±5.6 per cent per minute is found, in agreement with previously reported values. Morning and afternoon measurements on the same subject show that morning tear turnover rates are significantly higher than those in the afternoon (p<0.01), suggesting a circadian rhythm in tear flow. It is also concluded that use of a 10 per cent fluorescein solution can lead to a significant underestimation of tear turnover rates and that any resulting errors are likely to be larger for light coloured irises.Keywords
This publication has 14 references indexed in Scilit:
- The questionably dry eye.British Journal of Ophthalmology, 1981
- Basic Tear FlowOphthalmology, 1980
- Basal Precorneal Tear Turnover in the Human EyeAmerican Journal of Ophthalmology, 1980
- Schirmer Test and Break-Up Time of Tear Film in Normal SubjectsAmerican Journal of Ophthalmology, 1979
- Ophthalmic fluorophotometry: an improved slit-lamp fluorophotometerMedical & Biological Engineering & Computing, 1979
- An improved objective slit-lamp fluorophotometer using tungsten-halogen lamp excitation and synchronous detection.British Journal of Ophthalmology, 1977
- Slit Lamp FluorophotometryOptical Engineering, 1976
- Evaluation of the Schirmer Tear TestSouthern Medical Journal, 1970
- TEAR SECRETION IN NORMAL EYESActa Ophthalmologica, 1965
- LACRIMATION IN NORMAL EYESArchives of Ophthalmology (1950), 1953