Computational model for simulation of vascular adaptation following vascular access surgery in haemodialysis patients
Authors:
- Katia PasseraKPKatia Passera
- Wouter HubertsWHWouter Huberts
- Lorenzo BottiLBLorenzo Botti
- Luca AntigaLALuca Antiga
- Andrea RemuzziARAndrea Remuzzi
- 21 November 2012
- journal article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 17 (12) , 1358-1367
Abstract
An important number of surgical procedures for creation of vascular access (VA) in haemodialysis patients still results in non-adequate increase in blood flow (non-maturation). The rise in blood flow in arteriovenous shunts depends on vascular remodelling. Computational tools to predict the outcome of VA surgery would be important in this clinical context. The aim of our investigation was then to develop a 0D/1D computational model of arm vasculature able to simulate vessel wall remodelling and related changes in blood flow. We assumed that blood vessel remodelling is driven by peak wall shear stress. The model was calibrated with previously reported values of radial artery diameter and blood flow after end-to-end distal fistula creation. Good agreement was obtained between predicted changes in VA flow and in arterial diameter after surgery and corresponding measured values. The use of this computational model may allow accurate vascular surgery planning and ameliorate VA surgery outcomes.Keywords
This publication has 25 references indexed in Scilit:
- Arterial properties along the upper arm in humans: age-related effects and the consequence of anatomical locationJournal of Applied Physiology, 2010
- Hemodynamic shear stress and the endothelium in cardiovascular pathophysiologyNature Clinical Practice Cardiovascular Medicine, 2008
- Heterogeneous remodelling of the ascending and descending aorta with ageJournal of Human Hypertension, 2007
- Why don't fistulas mature?Kidney International, 2006
- The effect of flow changes on the arterial system proximal to an arteriovenous fistula for hemodialysisUltrasound in Medicine & Biology, 2005
- Shear stress depends on vascular territory: comparison between common carotid and brachial arteryJournal of Applied Physiology, 2003
- Increasing arteriovenous fistulas in hemodialysis patients: Problems and solutionsKidney International, 2002
- Low-pressure environment and remodelling of the forearm vein in Brescia-Cimino haemodialysis accessNephrology Dialysis Transplantation, 2002
- Flow-mediated endothelial mechanotransductionPhysiological Reviews, 1995
- Chronic Hemodialysis Using Venipuncture and a Surgically Created Arteriovenous FistulaThe New England journal of medicine, 1966