In vivo transit dosimetry methodology for whole breast intensity modulated radiation therapy
Open Access
- 26 March 2025
- journal article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (5) , e70072
Abstract
Background: In vivo transit dosimetry using an electronic portal imaging device (EPID‐IVTD) is an important tool for verifying the accuracy of radiation therapy treatments. Despite its potential, the implementation of EPID‐IVTD in breast intensity modulated radiation therapy (IMRT) treatments has not yet been standardized, limiting its clinical adoption. A standardized EPID‐IVTD method could enhance treatment accuracy and improve patient safety in routine clinical practice.Purpose: This study aims to develop a method for EPID‐IVTD for whole breast IMRT treatment.Methods: Gamma passing rates (GPRs) analysis was the basis of the work conducted on a dataset of 50 patients. The first phase of the work focused on the identification of the reference fraction. In the second phase a method for performing EPID‐IVTD was implemented. Lower‐tolerance and ‐action limits (l‐TL and l‐AL), as introduced by AAPM TG 218, were employed to determine the reference fraction and used as alert and alarm thresholds, respectively, in EPID‐IVTD monitoring.Results: The first treatment fraction demonstrated the best dosimetric agreement with the theoretical plan and was therefore used as the reference in the second phase of the study. EPID‐IVTD results showed that 75% of the GPRs ranged from 97.5% to 99.9%, 93.83% were above the l‐TL, 4.31% fell between l‐TL and l‐AL, and 1.86% were below l‐AL.Conclusions: A method for the implementation of an effective EPID‐IVTD in whole breast IMRT treatment was developed and is now routinely applied at our center, enabling efficient monitoring in clinical practice.Keywords
This publication has 35 references indexed in Scilit:
- AAPM Task Group Report 307: Use of EPIDs for Patient‐Specific IMRT and VMAT QAMedical Physics, 2023
- Gamma passing rates of daily EPID transit images correlate to PTV coverage for breast cancer IMRT treatment plansJournal of Applied Clinical Medical Physics, 2023
- In vivo dosimetry in low-voltage IORT breast treatments with XR-RV3 radiochromic filmPhysica Medica, 2021
- Electron radiotherapy (IOERT) for applications outside of the breast: Dosimetry and influence of tissue inhomogeneitiesPhysica Medica, 2020
- The effect of the choice of patient model on the performance of in vivo 3D EPID dosimetry to detect variations in patient position and anatomyMedical Physics, 2019
- Evaluation of interfraction setup variations for postmastectomy radiation therapy using EPID‐based in vivo dosimetryJournal of Applied Clinical Medical Physics, 2019
- Site‐specific alert criteria to detect patient‐related errors with 3D EPID transit dosimetryMedical Physics, 2018
- Tolerance limits and methodologies forIMRTmeasurement‐based verificationQA:Recommendations ofAAPMTask Group No. 218Medical Physics, 2018
- Effects of Setup Errors and Shape Changes on Breast RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Generalized EPID calibration for in vivo transit dosimetryPhysica Medica, 2011