Effective dose to patients from chest examinations with tomosynthesis
Authors:
- 16 March 2010
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 139 (1-3) , 153-158
Abstract
Chest tomosynthesis, which refers to the principle of collecting low-dose projections of the chest at different angles and using these projections to reconstruct section images of the chest, is an imaging technique recently introduced to health care. The main purpose of the present work was to determine the average effective dose to patients from clinical use of chest tomosynthesis. Exposure data for two chest radiography laboratories with tomosynthesis option (Definium 8000 with VolumeRAD option, GE Healthcare, Chalfont St. Giles, UK) were registered for 20 patients with a weight between 60 and 80 kg (average weight of 70.2 kg). The recorded data were used in the Monte Carlo program PCXMC 2.0 (STUK—Radiation and Nuclear Safety Authority, Helsinki, Finland) to determine the average effective dose for each projection. The effective dose for the chest tomosynthesis examination, including a scout view and the tomosynthesis acquisition, was finally obtained by adding the effective doses from all projections. Using the weighting factors given in ICRP 103, the average effective dose for the examination was found to be 0.13 mSv, whereas the average effective dose for the conventional two-view chest radiography examination was 0.05 mSv. A conversion factor of 0.26 mSv Gy–1 cm–2 was found suitable for determining the effective dose from a VolumeRAD chest tomosynthesis examination from the total registered kerma-area product. In conclusion, the effective dose to a standard-sized patient (170 cm/70 kg) from a VolumeRAD chest tomosynthesis examination is ~2 % of an average chest CT and only two to three times the effective dose from the conventional two-view chest radiography examination.Keywords
This publication has 9 references indexed in Scilit:
- Simulation of dose reduction in tomosynthesisMedical Physics, 2009
- A Monte Carlo estimation of effective dose in chest tomosynthesisMedical Physics, 2009
- Effect of clinical experience of chest tomosynthesis on detection of pulmonary nodulesActa Radiologica, 2009
- Tomosynthesis imaging: At a translational crossroadsMedical Physics, 2009
- Comparison of Chest Tomosynthesis and Chest Radiography for Detection of Pulmonary Nodules: Human Observer Study of Clinical CasesRadiology, 2008
- Effective Doses in Radiology and Diagnostic Nuclear Medicine: A CatalogRadiology, 2008
- Digital tomosynthesis of the chest for lung nodule detection: Interim sensitivity results from an ongoing NIH‐sponsored trialMedical Physics, 2008
- Digital x-ray tomosynthesis: current state of the art and clinical potentialPhysics in Medicine & Biology, 2003
- Recommendations of the international commission on radiological protection and of the international commission on radiological units, 19501951