Evaluation of a rapid colorimetric assay for detection of bacterial contamination in apheresis and pooled random‐donor platelet units
- 18 March 2014
- journal article
- Published by Wiley in Transfusion
- Vol. 54 (6) , 1634-1641
Abstract
Background: Despite existing strategies, bacterial contamination of platelets (PLTs) remains a problem, and reliable testing near the time of use is needed. We evaluated the BacTx assay (Immunetics, Inc.), a rapid colorimetric assay for detection of bacterial peptidoglycan, for this purpose.Study Design and Methods: Apheresis‐ and whole blood–derived PLT units, the latter tested in 6‐unit pools, inoculated with 10 representative bacterial species (eight aerobic, two anaerobic), were tested with the BacTx assay at two sites to determine analytic sensitivity and time to detection. Specificity on sterile PLTs and reproducibility across different PLT units and assay kit lots was also determined.Results: Analytical sensitivity for the 10 bacterial species ranged from 6.3 × 102 to 7.6 × 104 colony‐forming units (CFUs)/mL. In time‐to‐detection studies after inoculation of PLTs with 0.7 to 5.3 CFUs/mL, 10 replicates of all eight aerobic species were positive when bacterial titers were above the analytic sensitivity detection limit, which occurred at 48 hours for 60 PLT units and at 72 hours for the remaining 4 units, as well as at 7 days for all units. Specificity was 99.8% and reproducibility was 100%.Conclusions: The BacTx assay had an analytical sensitivity below the 105 CFUs/mL threshold of clinical significance, detected all eight aerobic bacterial species 48 to 72 hours after inoculation as well as at 7 days, and had high specificity and reproducibility. These findings suggest that the BacTx assay will be a valuable test for detection of clinically relevant levels of bacterial contaminants in PLT units and pools near time of use.Keywords
Funding Information
- Immunetics
This publication has 20 references indexed in Scilit:
- Survey of methods used to detect bacterial contamination of platelet products in the United States in 2011Transfusion, 2013
- Detection of bacterial contamination in prestorage culture‐negative apheresis platelets on day of issue with the Pan Genera Detection testTransfusion, 2011
- Prevalence, incidence, and residual risk of major blood‐borne infections among apheresis collections to the American Red Cross Blood Services, 2004 through 2008Transfusion, 2010
- Prevalence, incidence, and residual risk of human immunodeficiency virus and hepatitis C virus infections among United States blood donors since the introduction of nucleic acid testingTransfusion, 2010
- Current incidence and residual risk of hepatitis B infection among blood donors in the United StatesTransfusion, 2009
- Limiting and detecting bacterial contamination of apheresis platelets: inlet‐line diversion and increased culture volume improve component safetyTransfusion, 2009
- Transfusion medicine and safetyBiologicals, 2009
- Screening platelet concentrates for bacterial contamination: low numbers of bacteria and slow growth in contaminated units mandate an alternative approach to product safetyVox Sanguinis, 2008
- The residual risk of sepsis: modeling the effect of concentration on bacterial detection in two‐bottle culture systems and an estimation of false‐negative culture ratesTransfusion, 2007
- Bacterial screening of apheresis platelets and the residual risk of septic transfusion reactions: the American Red Cross experience (2004‐2006)Transfusion, 2007