Development and validation of a multiresidue method for the analysis of 151 pesticide residues in strawberry by gas chromatography coupled to a triple quadrupole mass analyzer
Authors:
- Patricia Plaza BolañosPatricia Plaza Bolaños
- Patricia PlazaPPPatricia Plaza
- José Luis Fernández MorenoJMJosé Luis Fernández Moreno
- Deyana D. ShterevaDSDeyana D. Shtereva
- Antonia Garrido FrenichAFAntonia Garrido Frenich
- José Luis Martínez VidalJVJosé Luis Martínez Vidal
- 18 June 2007
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 21 (14) , 2282-2294
Abstract
A new method was developed and validated for the simultaneous determination of 151 pesticide residues in strawberry by gas chromatography coupled to a triple quadrupole mass analyzer (GC/QqQ‐MS/MS), mainly using the selected reaction monitoring (SRM) mode. The list of target compounds included various classes of pesticides such as organochlorine (OCPs), organophosphorus (OPPs), carbamates, pyrethroids, triazoles and dicarboximides. A single extraction of 10 g of sample with acetonitrile followed by liquid‐liquid partition formed by the addition of 4 g of MgSO 4 and 1 g of NaCl was applied in sample preparation. Cleanup of the extracts was carried out by applying dispersive solid‐phase extraction (D‐SPE) with primary secondary amine (PSA). The analysis time was 21 min. The method was subjected to a thorough validation procedure. The recovery data were obtained by spiking blank samples at two concentration levels (11.5 and 50 µg/kg), yielding recoveries in the range 70–110%. Precision values expressed as relative standard deviation (RSD) were lower than 18% and 22% for the intraday and interday precision, respectively. Linearity was studied in the range 10–200 µg/kg and determination coefficients (R 2 ) were higher than 0.98% for all compounds. Limits of detection (LODs) and limits of quantification (LOQs) were established as 4 and 10 µg/kg, respectively. The overall uncertainty of the method was estimated at two different concentrations (11.5 and 50 µg/kg), being lower than 25% in both cases. According to the validation data and performance characteristics as well as the high sample throughput and low cost, the proposed method is suitable for routine application. Copyright © 2007 John Wiley & Sons, Ltd.Keywords
This publication has 30 references indexed in Scilit:
- Comparison of pressurized liquid extraction and microwave assisted extraction for the determination of organochlorine pesticides in vegetablesTalanta, 2007
- Application of hollow fiber supported liquid membrane extraction to the simultaneous determination of pesticide residues in vegetables by liquid chromatography/mass spectrometryRapid Communications in Mass Spectrometry, 2006
- Multiresidue analysis of organochlorine and organophosphorus pesticides in muscle of chicken, pork and lamb by gas chromatography–triple quadrupole mass spectrometryAnalytica Chimica Acta, 2006
- Simultaneous determination of 109 pesticides in unpolished rice by a combination of gel permeation chromatography and Florisil column purification, and gas chromatography/mass spectrometryRapid Communications in Mass Spectrometry, 2006
- Validation of a gas chromatography/triple quadrupole mass spectrometry based method for the quantification of pesticides in food commoditiesRapid Communications in Mass Spectrometry, 2005
- Comparison of Different Mass Spectrometric Techniques Combined with Liquid Chromatography for Confirmation of Pesticides in Environmental Water Based on the Use of Identification PointsAnalytical Chemistry, 2004
- Comparison of solid-phase extraction sorbents for cleanup in pesticide residue analysis of fresh fruits and vegetablesJournal of Separation Science, 2002
- Assessment of uncertainty in pesticide multiresidue analytical methods: main sources and estimationAnalytica Chimica Acta, 2002
- Large-volume injection in gas chromatographic trace analysis using temperature-programmable (PTV) injectorsTrAC Trends in Analytical Chemistry, 1996
- injection techniques in capillary GCAnalytical Chemistry, 1994