Validity of freehand three-dimensional ultrasound system in measurement of three-dimensional surface shape of shoulder muscles
Preprint
Abstract
Freehand three-dimensional ultrasound (3DUS) system is a promising technique for accurately assessing muscle morphology. However, its accuracy has been validated mainly in terms of volume by examining lower limb muscles. This study aimed to validate 3DUS in the measurements of 3D surface shape and volume by comparing them with MRI measurements while ensuring the reproducibility of participant posture by focusing on the shoulder muscles. The supraspinatus, infraspinatus, and posterior deltoid muscles of 10 healthy males were scanned using 3DUS and MRI while secured by an immobilization support customized for each participant. A 3D surface model of each muscle was created from the 3DUS and MRI methods, and the agreement between them was assessed. For the muscle volume, the mean difference between the two models was within −0.51 cm 3 . For the 3D surface shape, the distances between the closest points of the two models and Dice similarity coefficient were calculated. The results showed that the median surface distance was less than 1.21 mm and Dice similarity coefficient was larger than 0.85. These results suggest that, given the above error is permitted, 3DUS can be used as an alternative to MRI in measuring volume and surface shape, even for the shoulder muscles.Keywords
This publication has 23 references indexed in Scilit:
- Muscle structural assembly and functional consequencesJournal of Experimental Biology, 2016
- The Generalized Log-Ratio Transformation: Learning Shape and Adjacency Priors for Simultaneous Thigh Muscle SegmentationIEEE Transactions on Medical Imaging, 2015
- Skeletal muscle design to meet functional demandsPhilosophical Transactions of the Royal Society B: Biological Sciences, 2011
- 3D Freehand Ultrasound for in vivo Determination of Human Skeletal Muscle VolumeUltrasound in Medicine & Biology, 2009
- Validation of a freehand 3D ultrasound system for morphological measures of the medial gastrocnemius muscleJournal of Biomechanics, 2009
- The Determination of Muscle Volume with A Freehand 3D Ultrasonography SystemUltrasound in Medicine & Biology, 2007
- A review of calibration techniques for freehand 3-D ultrasound systemsUltrasound in Medicine & Biology, 2005
- Muscle volume is a major determinant of joint torque in humansActa Physiologica Scandinavica, 2001
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Simple proton spectroscopic imaging.Radiology, 1984