The Reliability, Validity, and Normative Data of Interpupillary Distance and Pupil Diameter Using Eye-Tracking Technology
Open Access
- 1 July 2017
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 6 (4) , 2
Abstract
Purpose: The purpose of this study was to determine the reliability of interpupillary distance (IPD) and pupil diameter (PD) measures using an infrared eye tracker and central point stimuli. Validity of the test compared to known clinical tools was determined, and normative data was established against which individuals can measure themselves. Methods: Participants (416) across various demographics were examined for normative data. Of these, 50 were examined for reliability and validity. Validity for IPD measured the test (RightEye IPD/PD) against the PL850 Pupilometer and the Essilor Digital CRP. For PD, the test was measured against the Rosenbaum Pocket Vision Screener (RPVS). Reliability was analyzed with intraclass correlation coefficients (ICC) between trials with Cronbach's alpha (CA) and the standard error of measurement for each ICC. Convergent validity was investigated by calculating the bivariate correlation coefficient. Results: Reliability results were strong (CA > 0.7) for all measures. High positive significant correlations were found between the RightEye IPD test and the PL850 Pupilometer (P < 0.001) and Essilor Digital CRP (P < 0.001) and for the RightEye PD test and the RPVS (P < 0.001). Conclusions: Using infrared eye tracking and the RightEye IPD/PD test stimuli, reliable and accurate measures of IPD and PD were found. Results from normative data showed an adequate comparison for people with normal vision development. Translational Relevance: Results revealed a central point of fixation may remove variability in examining PD reliably using infrared eye tracking when consistent environmental and experimental procedures are conducted.Keywords
This publication has 25 references indexed in Scilit:
- Dark-light Change of Iris Parameters and Related Factors Among American Caucasians, American Chinese, and Mainland ChineseCurrent Eye Research, 2012
- Age, gender, corneal diameter, corneal curvature and central corneal thickness in Nigerians with normal intra ocular pressureJournal of Optometry, 2012
- Making sense of Cronbach's alphaInternational Journal of Medical Education, 2011
- Comparison of 2 monocular pupillometers and an autorefractor for measurement of the dark-adapted pupil diameterJournal of Cataract & Refractive Surgery, 2011
- Comparison of Rosenbaum Pupillometry Card Using Red and Blue Light to Colvard and Iowa PupillometersJournal of Refractive Surgery, 2010
- Comparison of the Colvard, Procyon, and Neuroptics Pupillometers for Measuring Pupil Diameter Under Low Ambient IlluminationJournal of Refractive Surgery, 2010
- Quantification of heterophoria and phoria adaptation using an automated objective system compared to clinical methodsOphthalmic and Physiological Optics, 2010
- The adaptive effect of narrowing the interocular separation on the AC/A ratioVision Research, 2005
- QuantifyJournal of Cataract & Refractive Surgery, 2002
- A subjective method for the measurement of monochromatic* aberrations of the eyeJournal of the Optical Society of America, 1977