Correlation between AV synchrony and device collected AM‐VP sequence counter in atrioventricular synchronous leadless pacemakers: A real‐world assessment
Open Access
- 15 November 2022
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 34 (1) , 197-206
Abstract
Introduction: Micra atrioventricular (AV) provides leadless atrioventricular synchronous pacing by sensing atrial contraction (A4 signal). Real‐world operation and reliability of AV synchrony (AVS) assessment using device data have not been described. The purposes of this study were to (1) assess the correlation between AVS and atrial mechanical sensed‐ventricular pacing (AM‐VP) percentages in patients with permanent high‐degree AV block and (2) report on the real‐world effectiveness of Micra AV.Methods: The correlation between ECG‐determined AVS in‐clinic and device‐collected %AM‐VP was assessed using data from 40 patients with high‐degree AV block enrolled in the Micra Atrial tRacking using a Ventricular AccELerometer (MARVEL) 2 study. A retrospective analysis to assess continuously‐sampled %AM‐VP since last session, device programming, and electrical parameters was performed using Micra AV transmissions from the Medtronic CareLink database. Patients with transmissions ≥180 days postimplant were included.Results: Among the 40 MARVEL 2 AV block patients with a median %VP of 99.7%, AVS was highly correlated with AM‐VP (median AVS 87.1%, median AM‐VP 79.1%; R2 = 0.764, p < .001). The CareLink cohort included 4384 patients programmed to VDD mode. The mean A4 amplitude was 2.3 ± 1.8 m/s2 at implant and 2.3 ± 1.6 m/s2 at 28 weeks. In patients with %VP >90% (n = 1662), the median %AM‐VP was 74.7%. For the full cohort, median %VP was 65.6% and median projected battery longevity was 10.5 years.Conclusion: In patients with a high pacing burden, %AM‐VP provides a reasonable estimation of AVS. The first large real‐world analysis of Micra AV patients with >90% VP showed stable atrial sensing over time with a median %AM‐VP, a correlate of AVS, of 74.7%.Keywords
Funding Information
- Medtronic
This publication has 10 references indexed in Scilit:
- Leadless atrioventricular synchronous pacing in an outpatient setting: Early lessons learned on factors affecting atrioventricular synchronyHeart Rhythm, 2022
- Optimizing mechanically sensed atrial tracking in patients with atrioventricular-synchronous leadless pacemakers: A single-center experienceHeart Rhythm O2, 2021
- Atrioventricular Synchronous Pacing Using a Leadless Ventricular PacemakerJACC: Clinical Electrophysiology, 2020
- Updated performance of the Micra transcatheter pacemaker in the real-world setting: A comparison to the investigational study and a transvenous historical controlHeart Rhythm, 2018
- A Leadless Intracardiac Transcatheter Pacing SystemNew England Journal of Medicine, 2016
- Value of VDD-pacing systems in patients with atrioventricular block: Experience over a decadeInternational Journal of Cardiology, 2007
- Optimal pacing for symptomatic AV block: a comparison of VDD and DDD pacing.2003
- Optimal Pacing for Symptomatic AV Block:Pacing and Clinical Electrophysiology, 2003
- Comparative three-year performance of chronic atrial sensing among eight different VDD systemsThe American Journal of Cardiology, 2002
- VDD(R) Pacing: Short‐ and Long‐Term Stability of Atrial Sensing with a Single Lead SystemPacing and Clinical Electrophysiology, 1996