Transient thermal analysis using both lumped-circuit approach and finite element method of a permanent magnet traction motor
Authors:
- Y.K. ChinYCY.K. Chin
- D.A. StatonDSD.A. Staton
- 6 April 2005
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. ol.1, 1027-1035
Abstract
This work presents the transient thermal analysis of a permanent magnet (PM) synchronous traction motor. The motor has magnets inset into the surface of the rotor to give a maximum field-weakening range of between 2 and 2.5. Both analytically based lumped circuit and numerical finite element methods have been used to simulate the motor. A comparison of the two methods is made showing the advantages and disadvantages of each. Simulation results are compared with practical measurements.Keywords
This publication has 5 references indexed in Scilit:
- Thermal sensitivity analysis for TEFC induction motors2004
- A permanent magnet synchronous motor for traction applications of electric vehicles2003
- Solving the more difficult aspects of electric motor thermal analysis2003
- Lumped parameter thermal model for electrical machines of TEFC designIEE Proceedings B Electric Power Applications, 1991
- Distribution of velocity and temperature between concentric rotating cylindersProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1935