Transmission of SARS-CoV-2 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event
Preprint
Abstract
During the 2020 COVID-19 pandemic, an outbreak occurred following attendance of a symptomatic index case at a regular weekly rehearsal on 10 March of the Skagit Valley Chorale (SVC). After that rehearsal, 53 members of the SVC among 61 in attendance were confirmed or strongly suspected to have contracted COVID-19 and two died. Transmission by the airborne route is likely. It is vital to identify features of cases such as this so as to better understand the factors that promote superspreading events. Based on a conditional assumption that transmission during this outbreak was by inhalation of respiratory aerosol, we use the available evidence to infer the emission rate of airborne infectious quanta from the primary source. We also explore how the risk of infection would vary with several influential factors: the rates of removal of respiratory aerosol by ventilation; deposition onto surfaces; and viral decay. The results indicate an emission rate of the order of a thousand quanta per hour (mean [interquartile range] for this event = 970 [680-1190] quanta per hour) and demonstrate that the risk of infection is modulated by ventilation conditions, occupant density, and duration of shared presence with an infectious individual. Practical Implications: During respiratory disease pandemics, group singing indoors should be discouraged or at a minimum carefully managed as singing can generate large amounts of airborne virus (quanta) if any of the singers is infected. Ventilation requirements for spaces that are used for singing (e.g., buildings for religious services and rehearsal/performance) should be reconsidered in light of the potential for airborne transmission of infectious diseases. Meetings of choirs and other kinds of singing groups during pandemics should only be in spaces that are equipped with a warning system of insufficient ventilation which may be detected with CO 2 “traffic light” monitors. Systems that combine the functions heating and ventilation (or cooling and ventilation) should be provided with a disclaimer saying “do not shut this system off when people are using the room; turning off the system will also shut down fresh air supply, which can lead to the spread of airborne infections.”Keywords
All Related Versions
- Published version: Indoor Air, 31 (2), 314.
This publication has 43 references indexed in Scilit:
- Aerosol and Surface Distribution of Severe Acute Respiratory Syndrome Coronavirus 2 in Hospital Wards, Wuhan, China, 2020Emerging Infectious Diseases, 2020
- Temporal profiles of viral load in posterior oropharyngeal saliva samples and serum antibody responses during infection by SARS-CoV-2: an observational cohort studyThe Lancet Infectious Diseases, 2020
- Air, Surface Environmental, and Personal Protective Equipment Contamination by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) From a Symptomatic PatientJAMA, 2020
- Aerodynamic analysis of SARS-CoV-2 in two Wuhan hospitalsNature, 2020
- Comparative dynamic aerosol efficiencies of three emergent coronaviruses and the unusual persistence of SARS-CoV-2 in aerosol suspensionsmedRxiv, 2020
- Toilets dominate environmental detection of SARS-CoV-2 virus in a hospitalmedRxiv, 2020
- Detection of Air and Surface Contamination by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in Hospital Rooms of Infected PatientsmedRxiv, 2020
- Viral load of SARS-CoV-2 in clinical samplesThe Lancet Infectious Diseases, 2020
- Transmission Potential of SARS-CoV-2 in Viral Shedding Observed at the University of Nebraska Medical CentermedRxiv, 2020
- Clinical Data on Hospital Environmental Hygiene Monitoring and Medical Staff Protection during the Coronavirus Disease 2019 OutbreakmedRxiv, 2020