Characterizing Uptake Kinetics of PAHs from the Air Using Polyethylene-Based Passive Air Samplers of Multiple Surface Area-to-Volume Ratios
- 24 March 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 38 (9) , 2701-2706
Abstract
Polyethylene passive sampling devices (PSDs) were deployed to investigate how passive samplers of multiple surface area-to-volume ratios could be used to characterize uptake kinetics for polyaromatic hydrocarbons (PAHs). Theoretically, uptake profiles for different thickness PSDs of the same surface area should show the following: where uptake is linear, the amount of compound accumulated in the different PSDs will be the same and where equilibrium is approached, the amount accumulated by the different PSDs will be proportional to sampler thickness. Polyethylene sheets of the same surface area and approximately 100 and 200 μm thickness were collected after 30, 60, and 90 days of exposure along with samples from a codeployed high volume sampler. Twelve priority pollutant PAHs could be routinely quantified in replicate PSDs. Overall, reproducibility between replicate PSDs was satisfactory, with normalized differences rarely exceeding 25%. The smallest analytes quantified, fluorene, phenanthrene, and anthracene, were shown to approach equilibrium during the deployment period, whereas uptake for fluoranthene and pyrene moved into the curvilinear stage. For most of the larger molecular weight PAHs such as indeno[1,2,3-cd]pyrene, uptake could be described using a linear uptake model. Preliminary sampling rates for the compounds which remained in the linear stage of uptake ranged between 0.5 and 1.5 m3 d-1 dm-2. Sampler to air partition coefficients were estimated for PAHs which approached equilibrium and predicted for some of the other compounds. Results suggest that a single deployment of PSDs with multiple surface area-to-volume ratios can be sufficient to determine whether uptake was linear or approaching equilibrium for a range of PAHs.Keywords
This publication has 8 references indexed in Scilit:
- Peer Reviewed: Equilibrium Sampling DevicesEnvironmental Science & Technology, 2003
- Characterization of Polymer-Coated Glass as a Passive Air Sampler for Persistent Organic PollutantsEnvironmental Science & Technology, 2003
- Polycyclic Aromatic Hydrocarbons in a Semiaquatic Plant and Semipermeable Membrane Devices Exposed to Air in ThailandEnvironmental Science & Technology, 2002
- Characterization and Comparison of Three Passive Air Samplers for Persistent Organic PollutantsEnvironmental Science & Technology, 2002
- Selecting internally consistent physicochemical properties of organic compoundsEnvironmental Toxicology and Chemistry, 2002
- Further Developments in the Use of Semipermeable Membrane Devices as Passive Air Samplers: Application to PCBsEnvironmental Science & Technology, 2001
- Passive sampling of atmospheric SOCs using tristearin-coated fibreglass sheetsAtmospheric Environment, 2000
- Application of semipermeable membrane devices (SPMDs) as passive air samplersChemosphere, 1993