The Effects of External Compression on Venous Blood Flow and Tissue Deformation in the Lower Leg
Authors:
- 1 December 1999
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 121 (6) , 557-564
Abstract
External pneumatic compression of the lower legs is effective as prophylaxis against deep vein thrombosis. In a typical application, inflatable cuffs are wrapped around the patient’s legs and periodically inflated to prevent stasis, accelerate venous blood flow, and enhance fibrinolysis. The purpose of this study was to examine the stress distribution within the tissues, and the corresponding venous blood flow and intravascular shear stress with different external compression modalities. A two-dimensional finite element analysis (FEA) was used to determine venous collapse as a function of internal (venous) pressure and the magnitude and spatial distribution of external (surface) pressure. Using the one-dimensional equations governing flow in a collapsible tube and the relations for venous collapse from the FEA, blood flow resulting from external compression was simulated. Tests were conducted to compare circumferentially symmetric (C) and asymmetric (A) compression and to examine distributions of pressure along the limb. Results show that A compression produces greater vessel collapse and generates larger blood flow velocities and shear stresses than C compression. The differences between axially uniform and graded-sequential compression are less marked than previously found, with uniform compression providing slightly greater peak flow velocities and shear stresses. The major advantage of graded-sequential compression is found at midcalf. Strains at the lumenal border are approximately 20 percent at an external pressure of 50 mmHg (6650 Pa) with all compression modalities.Keywords
This publication has 18 references indexed in Scilit:
- Cyclic Strain-Induced Plasminogen Activator Inhibitor-1 (PAI-1) Release from Endothelial Cells Involves Reactive Oxygen SpeciesBiochemical and Biophysical Research Communications, 1996
- Effectiveness of intermittent pneumatic leg compression for preventing deep vein thrombosis after total hip replacementJAMA, 1990
- Tissue plasminogen activator messenger RNA levels increase in cultured human endothelial cells exposed to laminar shear stressJournal of Cellular Physiology, 1990
- Fluid Flow Stimulates Tissue Plasminogen Activator Secretion by Cultured Human Endothelial CellsScience, 1989
- Effect of Optimization of Hemodynamics on Fibrinolytic Activity and Antithrombotic Efficacy of External Pneumatic Calf CompressionAnnals of Surgery, 1987
- Optimisation of indices of external pneumatic compression for prophylaxis against deep vein thrombosis: radionuclide gated imaging studiesCardiovascular Research, 1986
- Bioengineering Studies of Periodic External Compression as Prophylaxis Against Deep Vein Thrombosis—Part I: Numerical StudiesJournal of Biomechanical Engineering, 1982
- Unsteady flow in a collapsible tube subjected to external pressure or body forcesJournal of Fluid Mechanics, 1979
- Steady Flow in Collapsible TubesJournal of Biomechanical Engineering, 1977
- EFFECTS OF EXTERNAL PNEUMATIC INTERMITTENT COMPRESSION ON FIBRINOLYSIS IN MANThe Lancet, 1973