Biexponential diffusion decay in formalin‐fixed prostate tissue: Preliminary findings
Open Access
- 9 December 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 68 (3) , 954-959
Abstract
Magnetic resonance microimaging was used to measure diffusion decay over an extended b‐factor range in a formalin‐fixed normal prostate sample and a Gleason pattern 3+4 cancer tissue sample. The coefficients of biexponential fits to diffusion decay data from 1600 voxels of dimension 160 × 160 × 160 μm3 in each sample were correlated with underlying epithelial and stromal compartment partial volumes estimated from high‐resolution apparent diffusion coefficient (ADC) data (40 × 40 × 40 μm3 voxels) from the same tissue. In the normal tissue sample, the signal fractions of the low and high ADC components of the biexponential fits correlated linearly with partial volumes of epithelial tissue (R2 = 0.6) and stromal tissue (R2 = 0.5), respectively. Similar but weaker correlations were observed in the cancer sample. Epithelium‐containing high spatial resolution voxels appeared to be composed of ∼60% low ADC and ∼40% high ADC component. Stromal voxels appeared to be composed of ∼20% low ADC and ∼80% high ADC component. This preliminary report suggests that distinctly different diffusion properties in microscopically adjacent cell types contribute to the multiexponential diffusion decay phenomenon in prostate tissue. Magn Reson Med, 2012.Keywords
This publication has 14 references indexed in Scilit:
- 16 T Diffusion microimaging of fixed prostate tissue: Preliminary findingsMagnetic Resonance in Medicine, 2011
- Biexponential apparent diffusion coefficients in prostate cancerMagnetic Resonance Imaging, 2009
- Prostate magnetic resonance imaging: Multiexponential T2 decay in prostate tissueJournal of Magnetic Resonance Imaging, 2008
- Effects of temperature and aldehyde fixation on tissue water diffusion properties, studied in an erythrocyte ghost tissue modelMagnetic Resonance in Medicine, 2006
- Biexponential characterization of prostate tissue water diffusion decay curves over an extended b-factor rangeMagnetic Resonance Imaging, 2006
- Human erythrocyte ghosts: Exploring the origins of multiexponential water diffusion in a model biological tissue with magnetic resonanceMagnetic Resonance in Medicine, 2002
- MR microscopy of multicomponent diffusion in single neuronsMagnetic Resonance in Medicine, 2001
- Physical models of diffusion for polymer solutions, gels and solidsProgress in Polymer Science, 1999
- Exponential analysis in physical phenomenaReview of Scientific Instruments, 1999
- A Model for Diffusive Transport through a Spherical Interface Probed by Pulsed-Field Gradient NMRBiophysical Journal, 1998