Quantitative Performance of E-Scribe Warehouse in Detecting Quality Issues With Digital Annotated ECG Data From Healthy Subjects
- 1 May 2008
- journal article
- Published by Wiley in The Journal of Clinical Pharmacology
- Vol. 48 (5) , 538-546
Abstract
The US Food and Drug Administration recommends submission of digital electrocardiograms in the standard HL7 XML format into the electrocardiogram warehouse to support preapproval review of new drug applications. The Food and Drug Administration scrutinizes electrocardiogram quality by viewing the annotated waveforms and scoring electrocardiogram quality by the warehouse algorithms. Part of the Food and Drug Administration warehouse is commercially available to sponsors as the E‐Scribe Warehouse. The authors tested the performance of E‐Scribe Warehouse algorithms by quantifying electrocardiogram acquisition quality, adherence to QT annotation protocol, and T‐wave signal strength in 2 data sets: “reference” (104 digital electrocardiograms from a phase I study with sotalol in 26 healthy subjects with QT annotations by computer‐assisted manual adjustment) and “test” (the same electrocardiograms with an intentionally introduced predefined number of quality issues). The E‐Scribe Warehouse correctly detected differences between the 2 sets expected from the number and pattern of errors in the “test” set (except for 1 subject with QT misannotated in different leads of serial electrocardiograms) and confirmed the absence of differences where none was expected. E‐Scribe Warehouse scores below the threshold value identified individual electrocardiograms with questionable T‐wave signal strength. The E‐Scribe Warehouse showed satisfactory performance in detecting electrocardiogram quality issues that may impair reliability of QTc assessment in clinical trials in healthy subjects.Keywords
This publication has 19 references indexed in Scilit:
- Quality assessment of digital annotated ECG data from clinical trials by the FDA ECG warehouseExpert Opinion on Drug Safety, 2007
- Recommendations for the Standardization and Interpretation of the ElectrocardiogramCirculation, 2007
- Precision of QT Interval Measurement by Advanced Electrocardiographic EquipmentPacing and Clinical Electrophysiology, 2006
- Implications of methodological differences in digital electrocardiogram interval measurementJournal of Electrocardiology, 2006
- Clinical utility of the Food and Drug Administration Electrocardiogram Warehouse: a paradigm for the critical pathway initiativeJournal of Electrocardiology, 2005
- Drug‐Induced Torsades de Pointes and Implications for Drug DevelopmentJournal of Cardiovascular Electrophysiology, 2004
- Focus on issues in measuring and interpreting changes in the QTc interval durationEuropean Heart Journal Supplements, 2001
- How to Obtain and Analyze Electrocardiograms in Clinical TrialsAnnals of Noninvasive Electrocardiology, 1999
- Errors in manual measurement of QT intervals.Heart, 1994
- Prediction of sotalol-induced maximum steady-state QTc prolongation from single-dose administration in healthy volunteersClinical Pharmacology & Therapeutics, 1992