Fire Performance of Water-Cooled GFRP Columns. I: Fire Endurance Investigation
- 1 June 2011
- journal article
- research article
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 15 (3) , 404-412
Abstract
Structural fire endurance experiments were conducted on full-scale cellular glass fiber-reinforced (GFRP) columns under axial compression and subjected to ISO834 fire exposure from one side. Unprotected columns can resist fire for more than 30 min, which is sufficient for occupants to be evacuated from smaller buildings. The closed cellular cross-section prevented the rapid heating of the webs, which could therefore continue stabilizing the face sheet on the cold side against buckling. Water cooling was proven to offer an effective active fire-protection system. The structural function of the column could be maintained for two hours. Previously developed models were capable of accurately predicting the time-dependent temperature responses, modulus degradation, and time to failure.Keywords
This publication has 14 references indexed in Scilit:
- Modeling of mechanical response of FRP composites in fireComposites Part A: Applied Science and Manufacturing, 2009
- Structural Integrity of Composite Columns Subject to FireJournal of Composite Materials, 2009
- Modeling of stiffness of FRP composites under elevated and high temperaturesComposites Science and Technology, 2008
- Modeling of thermal responses for FRP composites under elevated and high temperaturesComposites Science and Technology, 2008
- Modeling of thermo-physical properties for FRP composites under elevated and high temperatureComposites Science and Technology, 2007
- Modelling the tension and compression strengths of polymer laminates in fireComposites Science and Technology, 2007
- Fire endurance of loaded and liquid-cooled GFRP slabs for constructionComposites Part A: Applied Science and Manufacturing, 2006
- Properties of composite materials for thermal analysis involving firesComposites Part A: Applied Science and Manufacturing, 2006
- An experimental and numerical study of the behaviour of glass fibre reinforced plastics (GRP) short columns at elevated temperaturesComposite Structures, 2004
- Thermal Expansion Coefficients of Composite Materials Based on Energy PrinciplesJournal of Composite Materials, 1968