Wall Thickness‐Guided vs. Voltage‐Guided Pulmonary Vein Isolation for Atrial Fibrillation
Open Access
- 27 October 2025
- journal article
- Published by Wiley in Journal of Arrhythmia
- Vol. 41 (5)
Abstract
Background: The efficacy and safety of tailored pulmonary vein isolation (PVI) guided by either left atrial wall thickness (LAWT) or bipolar voltage remain unclear. Objective: The aim of this prospective study was to evaluate the efficacy and safety of each ablation strategy. Methods: We conducted a prospective analysis of 97 patients with non‐valvular atrial fibrillation (AF) who underwent an initial RF catheter ablation procedure known as an extensive encircling PVI. Fifty patients underwent PVI using a wall thickness (WT)‐guided approach using ADAS 3D software and 47 patients using a voltage‐guided approach. In each strategy, high‐power short‐duration (HPSD) ablation was applied to regions with increased LAWT or elevated bipolar voltage, respectively, while very high‐power short‐duration (vHPSD) ablation was delivered to the remaining regions. Results: The first‐pass PVI rate tended to be higher in the WT‐guided group compared to the Voltage‐guided group (43 [86%] vs. 34 [72%], p = 0.09), and the incidence of acute PV reconnection (APVR) tended to be lower (5 [10%] vs. 11 [23%], p = 0.07). The proportion of patients with PV gaps (defined as the combined occurrence of first‐pass failure and/or APVR) was significantly lower in the WT‐guided group (10 [20%] vs. 18 [38%], p = 0.04). The multivariable‐adjusted analysis demonstrated that WT‐guided ablation was significantly more effective than Voltage‐guided ablation in preventing PV gaps. Both ablation strategies were performed without any procedural complications. Conclusions: WT‐guided ablation was associated with a significantly lower incidence of PV gaps than a conventional bipolar voltage‐guided strategy.Keywords
Funding Information
- Fukuda Denshi
This publication has 14 references indexed in Scilit:
- Clinical outcomes with very high power very short duration ablation for atrial fibrillation: The jury is still outJournal of Cardiovascular Electrophysiology, 2022
- 90 vs 50-Watt Radiofrequency Applications for Pulmonary Vein Isolation: Experimental and Clinical FindingsCirculation: Arrhythmia and Electrophysiology, 2022
- Structural Cardiac Remodeling in Atrial FibrillationJACC: Cardiovascular Imaging, 2021
- Modified ablation index: a novel determinant of a successful first-pass left atrial posterior wall isolationHeart and Vessels, 2021
- Comparison of In Vivo Tissue Temperature Profile and Lesion Geometry for Radiofrequency Ablation With High Power–Short Duration and Moderate Power–Moderate Duration: Effects of Thermal Latency and Contact Force on Lesion FormationCirculation: Arrhythmia and Electrophysiology, 2021
- Safety and Efficacy of High Power Shorter Duration Ablation Guided by Ablation Index or Lesion Size Index in Atrial Fibrillation Ablation: A Systematic Review and Meta-AnalysisJournal of Interventional Cardiology, 2021
- Epicardial Connections Involving Pulmonary VeinsCirculation: Arrhythmia and Electrophysiology, 2020
- Pulmonary Vein Isolation With Very High Power, Short Duration, Temperature-Controlled LesionsJACC: Clinical Electrophysiology, 2019
- The modified ablation index: a novel determinant of acute pulmonary vein reconnections after pulmonary vein isolationJournal of Interventional Cardiac Electrophysiology, 2019
- High-voltage zones within the pulmonary vein antra: Major determinants of acute pulmonary vein reconnections after atrial fibrillation ablationJournal of Interventional Cardiac Electrophysiology, 2017