A novel smartphone ophthalmic imaging adapter: User feasibility studies in Hyderabad, India
Open Access
- 1 January 2016
- journal article
- research article
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 64 (3) , 191-200
Abstract
Aim of Study: To evaluate the ability of ancillary health staff to use a novel smartphone imaging adapter system (EyeGo, now known as Paxos Scope) to capture images of sufficient quality to exclude emergent eye findings. Secondary aims were to assess user and patient experiences during image acquisition, interuser reproducibility, and subjective image quality. Materials and Methods: The system captures images using a macro lens and an indirect ophthalmoscopy lens coupled with an iPhone 5S. We conducted a prospective cohort study of 229 consecutive patients presenting to L. V. Prasad Eye Institute, Hyderabad, India. Primary outcome measure was mean photographic quality (FOTO-ED study 1–5 scale, 5 best). 210 patients and eight users completed surveys assessing comfort and ease of use. For 46 patients, two users imaged the same patient's eyes sequentially. For 182 patients, photos taken with the EyeGo system were compared to images taken by existing clinic cameras: a BX 900 slit-lamp with a Canon EOS 40D Digital Camera and an FF 450 plus Fundus Camera with VISUPAC™ Digital Imaging System. Images were graded post hoc by a reviewer blinded to diagnosis. Results: Nine users acquired 719 useable images and 253 videos of 229 patients. Mean image quality was ≥ 4.0/5.0 (able to exclude subtle findings) for all users. 8/8 users and 189/210 patients surveyed were comfortable with the EyeGo device on a 5-point Likert scale. For 21 patients imaged with the anterior adapter by two users, a weighted κ of 0.597 (95% confidence interval: 0.389–0.806) indicated moderate reproducibility. High level of agreement between EyeGo and existing clinic cameras (92.6% anterior, 84.4% posterior) was found. Conclusion: The novel, ophthalmic imaging system is easily learned by ancillary eye care providers, well tolerated by patients, and captures high-quality images of eye findings.Keywords
This publication has 13 references indexed in Scilit:
- Simple, Low-Cost Smartphone Adapter for Rapid, High Quality Ocular Anterior Segment Imaging: A Photo DiaryJournal of Mobile Technology in Medicine, 2014
- Simple, Inexpensive Technique for High-Quality Smartphone Fundus Photography in Human and Animal EyesJournal of Ophthalmology, 2013
- Smartphone Photography SafetyOphthalmology, 2012
- Nonmydriatic Digital Ocular Fundus Photography on the iPhone 3G: The FOTO-ED StudyArchives of Ophthalmology (1950), 2012
- Quality of Nonmydriatic Digital Fundus Photography Obtained by Nurse Practitioners in the Emergency Department: The FOTO-ED StudyOphthalmology, 2012
- Key factors determining success of primary eye care through vision centres in rural India: Patients′ perspectivesIndian Journal Of Ophthalmology, 2012
- Integrated model of primary and secondary eye care for underserved rural areas: The L V Prasad Eye Institute experienceIndian Journal Of Ophthalmology, 2012
- Smartphones in ophthalmologyIndian Journal Of Ophthalmology, 2012
- Novel Uses of Smartphones in OphthalmologyOphthalmology, 2010
- Research electronic data capture (REDCap)—A metadata-driven methodology and workflow process for providing translational research informatics supportJournal of Biomedical Informatics, 2009