Systematic Verification of Bioanalytical Similarity Between a Biosimilar and a Reference Biotherapeutic: Committee Recommendations for the Development and Validation of a Single Ligand-Binding Assay to Support Pharmacokinetic Assessments
- 3 October 2014
- journal article
- Published by Springer Nature in The AAPS Journal
- Vol. 16 (6) , 1149-1158
Abstract
For biosimilar drug development, it is critical to demonstrate similar physiochemical characteristics, efficacy, and safety of the biosimilar product compared to the reference product. Therefore, pharmacokinetic (PK) and immunogenicity (antidrug antibody, ADA) assays that allow for the demonstration of biosimilarity are critical. Under the auspices of the American Association of Pharmaceutical Scientists (AAPS) Ligand-Binding Assay Bioanalytical Focus Group (LBABFG), a Biosimilars Action Program Committee (APC) was formed in 2011. The goals of this Biosimilars APC were to provide a forum for in-depth discussions on issues surrounding the development and validation of PK and immunogenicity assays in support of biosimilar drug development and to make recommendations thereof. The Biosimilars APC’s recommendations for the development and validation of ligand-binding assays (LBAs) to support the PK assessments for biosimilar drug development are presented here. Analytical recommendations for the development and validation of LBAs to support immunogenicity assessments will be the subject of a separate white paper.Keywords
This publication has 9 references indexed in Scilit:
- Recommendations and requirements for the design of bioanalytical testing used in comparability studies for biosimilar drug developmentBioanalysis, 2011
- Workshop Report and Follow-Up—AAPS Workshop on Current Topics in GLP Bioanalysis: Assay Reproducibility for Incurred Samples—Implications of Crystal City RecommendationsThe AAPS Journal, 2009
- Appropriate calibration curve fitting in ligand binding assaysThe AAPS Journal, 2007
- Quantitative Bioanalytical Methods Validation and Implementation: Best Practices for Chromatographic and Ligand Binding AssaysPharmaceutical Research, 2007
- Workshop/conference report—Quantitative bioanalytical methods validation and implementation: Best practices for chromatographic and ligand binding assaysThe AAPS Journal, 2007
- Bioanalytical Method Validation for Macromolecules in Support of Pharmacokinetic StudiesPharmaceutical Research, 2005
- Recommendations for the Bioanalytical Method Validation of Ligand-Binding Assays to Support Pharmacokinetic Assessments of MacromoleculesPharmaceutical Research, 2003
- Validation of immunoassays for bioanalysis: a pharmaceutical industry perspectiveJournal of Pharmaceutical and Biomedical Analysis, 2000
- A comparison of the Two One-Sided Tests Procedure and the Power Approach for assessing the equivalence of average bioavailabilityJournal of Pharmacokinetics and Biopharmaceutics, 1987