Zonal network solution of temperature profiles in a ventilated wall module
- 9 December 2017
- journal article
- research article
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 11 (5) , 538-552
Abstract
A ventilated wall module is an outdoor air-intake device that can clean the drawn air, reduce heat loss or gain, and insulate outdoor noises. It contains a solar board, air cavities, and an air filter. This investigation proposes a zonal network model to efficiently predict temperature profiles in a ventilated wall module. The thermal network is established by applying an energy balance to each network node. The outdoor temperature, indoor temperature, and solar irradiation intensity are specified as boundary parameters. The proposed model is validated by the measured temperatures in a prototype model. The results show that the proposed model provides reasonably accurate temperatures with a maximum gap of 3°C between the prediction and the measurement. The temperature profiles approach straight lines when the mass flow rate significantly increases. A similar trend is observed when the solar irradiation intensity, the solar board absorptivity, or the glass transmitivity dramatically decreases.Keywords
Funding Information
- China National Key Research and Development Program (2016YFC0700500)
- National Natural Science Foundation of China (50978039, 51622804)
This publication has 42 references indexed in Scilit:
- Energy performance of a ventilated façade by simulation with experimental validationApplied Thermal Engineering, 2014
- Calculation of overall thermal transfer value (OTTV) for commercial buildings constructed with naturally ventilated double skin façade in subtropical Hong KongEnergy and Buildings, 2014
- Numerical analysis of the most appropriate heat transfer correlations for free ventilated double skin photovoltaic façadesApplied Thermal Engineering, 2013
- Solar Engineering of Thermal Processes2013
- An experimentally validated mathematical and CFD model of a supply air window: Forced and natural flowEnergy and Buildings, 2013
- A Simulation of the Thermal Performance of a Small Solar Chimney Already Installed in a BuildingJournal of Solar Energy Engineering, 2012
- Numerical analysis of heat transfer in a passive solar composite wall with porous absorberApplied Thermal Engineering, 2008
- Air flow and thermal efficiency characteristics in solar chimneys and Trombe WallsEnergy and Buildings, 2007
- Numerical analysis of the thermal behaviour of ventilated glazed facades in Mediterranean climates. Part I: development and validation of a numerical modelSolar Energy, 2003
- An experimental investigation of a solar chimney model with uniform wall heat fluxBuilding and Environment, 2003