Abstract
Capacity fade and exchange current density of H2O/H2 system have been compared in conditions of long-standing cycling for powder composite electrodes based on (i) Sm0.4Zn0.6Fe2O4 ferrite spinel and (ii) LaNi4.5Co0.5 intermetallic compound. Changes of both quantities have been presented versus electrodes exposure time in strong alkaline solutions, at room temperature. Corrosion rate of semiconducting ferrite spinel is about 2.5 times lower than that of the intermetallic material. Consequently, capacity half-time is distinctly longer for the ferrite electrode. On the other hand, exchange current density of H2O/H2 system for ferrite spinel is extraordinarily low, on the level of 7 – 8 mA/g. It is suggested surface modification of the ferrite spinel material to improve its catalytic properties towards H2O/H2 redox system.