Amperometric ATP Microbiosensors for the Analysis of Chemosensitivity at Rat Carotid Bodies
Authors:
- 6 May 2008
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (11) , 3991-3998
Abstract
The physiological application of amperometric adenosine triphosphate (ATP) microbiosensors for characterizing the stimulus-response at rat carotid bodies superfused with high potassium concentrations, during normoxic hypercapnia, and during hypoxia is demonstrated using the peripheral arterial chemoreceptors in the carotid body of rats as a model system. Amperometric microbiosensors based on glucose oxidase (GOD) and hexokinase (HEX) immobilized within a polymer matrix at the surface of Pt disk microelectrodes (diameter: 25 µm) are positioned at a distance of approximately 100 µm above the carotid body surface for detecting extracellular ATP. A linear calibration function of ATP microbiosensors in the physiologically relevant concentration range of 0–40 µM ATP enables quantitative detection of ATP released at the carotid body surface in response to physiological stimuli. It is shown that these stimuli induce extracellular ATP release from the carotid body at levels of 4–10 µM. Other electroactive neurotransmitters such as, e.g., catecholamines are coreleased by the carotid body at hypercapnic, hypoxic and high-potassium stimulus, are simultaneously detected utilizing a dual-electrode assembly with an ATP microbiosensor and a second bare channel providing a colocalized reference measurement for ATP quantification.Keywords
This publication has 41 references indexed in Scilit:
- Behaviour of nucleotides and oligonucleotides in potentiometric HPLC detectionAnalytica Chimica Acta, 2005
- Listening to the brain: microelectrode biosensors for neurochemicalsTrends in Biotechnology, 2005
- ATP Released via Gap Junction Hemichannels from the Pigment Epithelium Regulates Neural Retinal Progenitor ProliferationNeuron, 2005
- Microelectrode Biosensor for Real-Time Measurement of ATP in Biological TissueAnalytical Chemistry, 2005
- Acetylcholine and Choline Amperometric Enzyme Sensors Characterized in Vitro and in VivoAnalytical Chemistry, 2004
- A three-enzyme microelectrode sensor for detecting purine release from central nervous systemBiosensors and Bioelectronics, 2003
- Rapid adenosine release in the nucleus tractus solitarii during defence response in rats: real‐time measurement in vivoThe Journal of Physiology, 2002
- Adenosine release in nucleus tractus solitarii does not appear to mediate hypoxia‐induced respiratory depression in ratsThe Journal of Physiology, 2002
- Mechanisms of Glutamate Metabolic Signaling in Retinal Glial (Müller) CellsJournal of Neuroscience, 2000
- A Temporary Local Energy Pool Coupled to Neuronal Activity: Fluctuations of Extracellular Lactate Levels in Rat Brain Monitored with Rapid‐Response Enzyme‐Based SensorJournal of Neurochemistry, 1997