Suppression of thermal transients in advanced LIGO interferometers using CO 2 laser preheating
- 2 May 2018
- journal article
- research article
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 35 (11) , 115006
Abstract
In high optical power interferometric gravitational wave detectors, such as Advanced LIGO, the thermal effects due to optical absorption in the mirror coatings and the slow thermal response of fused silica substrate cause time dependent changes in the mirror profile. After locking, high optical power builds up in the arm cavities. Absorption induced heating causes optical cavity transverse mode frequencies to drift over a period of hours, relative to the fundamental mode. At high optical power this can cause time dependent transient parametric instability, which can lead to interferometer disfunction. In this paper, we model the use of CO 2 laser heating designed to enable the interferometer to be maintained in a thermal condition such that transient changes in the mirrors are greatly reduced. This can minimize transient parametric instability and compensate dark port power fluctuations. Modeling results are presented for both single compensation where a CO 2 laser acting on one test mass per cavity, and double compensation using one CO 2 laser for each test mass. Using parameters of the LIGO Hanford Observatory X-arm as an example, single compensation allows the maximum mode frequency shift to be limited to 6% of its uncompensated value. However, single compensation causes transient degradation of the contrast defect. Double compensation minimise contrast defect degradation and reduces transients to less than 1% if the CO 2 laser spot is positioned within 2 mm of the cavity beam position.Keywords
This publication has 27 references indexed in Scilit:
- Thermal effects and their compensation in Advanced VirgoJournal of Physics: Conference Series, 2012
- Parametric instabilities in advanced gravitational wave detectorsClassical and Quantum Gravity, 2010
- Thermal lensing compensation principle for the ACIGA's High Optical Power Test Facility Test 1General Relativity and Gravitation, 2005
- Analysis of parametric oscillatory instability in power recycled LIGO interferometerPhysics Letters A, 2002
- Adaptive thermal compensation of test masses in advanced LIGOClassical and Quantum Gravity, 2002
- Parametric oscillatory instability in Fabry–Perot interferometerPhysics Letters A, 2001
- Compensation for thermal effects in mirrors of gravitational wave interferometersThe European Physical Journal D, 2001
- An introduction to Pound–Drever–Hall laser frequency stabilizationAmerican Journal of Physics, 2001
- Fabry-Perot cavity gravity-wave detectors1991
- Laser Beams and ResonatorsApplied Optics, 1966