Image distortion in MRI‐based polymer gel dosimetry of Gamma Knife stereotactic radiosurgery systems
Authors:
- Yoichi WatanabeYWYoichi Watanabe
- Gerard M. PereraGPGerard M. Perera
- Robertus B. MooijRMRobertus B. Mooij
- 16 April 2002
- journal article
- Published by Wiley in Medical Physics
- Vol. 29 (5) , 797-802
Abstract
We have studied effects of MR (magnetic resonance) image distortion on polymer gel dosimetry of Gamma Knife stereotactic radiosurgery systems. MR images of BANG polymer gel phantoms were acquired by using a Hahn spin-echo sequence and a fast 3D imaging GRASS sequence. Image artifacts were studied by varying the directions of frequency encoding and the receiver bandwidth. The phantoms were also CT (computed tomography) scanned. The studies showed that the measured dose distributions are shifted by 1.8+/-0.5 mm (2 pixels) in the frequency encoding direction. The magnitude of the shift is inversely proportional to the receiver bandwidth in agreement with theory. Comparison of MRI with CT showed the same image shift. We concluded that the discrepancy is caused by MR image distortion due to a difference in susceptibility effects between the phantom and the fiducial markers of the Leksell localization box.Keywords
This publication has 13 references indexed in Scilit:
- High-resolution dose profile studies based on MR Imaging with polymer BANGTM gels in stereotactic radiation techniquesMagnetic Resonance Imaging, 2000
- Quality assurance for the Leksell gamma unit: Considering magnetic resonance image-distortion and delineation failure in the targeting of the internal auditory canalMedical Physics, 1999
- MRI Distortion and Stereotactic Neurosurgery Using the Cosman-Roberts-Wells and Leksell FramesStereotactic and Functional Neurosurgery, 1996
- An Evaluation of the Accuracy of Magnetic-Resonance-Guided Gamma Knife SurgeryStereotactic and Functional Neurosurgery, 1996
- Magnetic resonance image—directed stereotactic neurosurgery: use of image fusion with computerized tomography to enhance spatial accuracyJournal of Neurosurgery, 1995
- Characterization of Spatial Distortion in Magnetic Resonance Imaging and Its Implications for Stereotactic SurgeryNeurosurgery, 1994
- Three-dimensional dose mapping from gamma knife treatment using a dosimeter gel and MR-imagingRadiotherapy and Oncology, 1992
- A Comparison between Magnetic Resonance Imaging and Computed Tomography for Stereotactic Coordinate DeterminationNeurosurgery, 1992
- Correction of spatial distortion in magnetic resonance angiography for radiosurgical treatment planning of cerebral arteriovenous malformationsMagnetic Resonance Imaging, 1992
- Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imagingMagnetic Resonance Imaging, 1992