An extremely stable and sensitive end-column electrochemical detector based on heated copper microdisk electrode with direct current for CE and CE-Chip
- 16 February 2010
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 135 (5) , 1124-1130
Abstract
A heated copper microdisk electrode (HCME) was fabricated and successfully applied to capillary electrophoresis (CE) and CE-Chip as an electrochemical detector (ECD) for the detection of three carbohydrates and shikimic acid (SA) in Illicium verum Hook F., respectively. The temperature of HCME was heated by twin-wire-wound coil with direct current to reduce the magnetic interference. Coupled with CE and CE-chip, this detector exhibits both extremely stable and sensitive performance at elevated temperature compared with that at room temperature. In successive detection of three carbohydrates and shikimic acid (SA), the HCME exhibits very stable response with RSD of ca. 2% with elevated temperature without renewing the electrode, while at room temperature, RSD of ca. 20% is obtained. This is very important in practical applications that tedious works, such as polishing and re-fixing the electrode at each detection, can be therefore avoided. In addition, the sensitivity is about 2 ∼ 6 time increased, and the linear range is about an order wider at elevated temperature (ca. 60 °C) than that at room temperature (ca. 25 °C).Keywords
This publication has 44 references indexed in Scilit:
- Highly enhanced electrocatalytic oxidation of glucose and shikimic acid at a disposable electrically heated oxide covered copper electrodeChemical Communications, 2009
- Rapid hydrolysis and electrochemical detection of trace carbofuran at a disposable heated screen-printed carbon electrodeThe Analyst, 2008
- Amperometric Detection of Carbohydrates with a Portable Silicone/Quartz Capillary Microchip by Designed Fracture SamplingAnalytical Chemistry, 2007
- Shikimic Acid Accumulation in Field-Grown Corn (Zea mays) Following Simulated Glyphosate DriftJournal of Agricultural and Food Chemistry, 2007
- Capillary electrophoresis with microwave-enhanced electrochemical detectionThe Analyst, 2006
- Electrochemistry of nicotinamide adenine dinucleotide (reduced) at heated platinum electrodesAnalytica Chimica Acta, 2005
- Separation of inorganic and organic anions by capillary zone electrophoresis with simultaneous indirect UV and conductivity detectionElectrophoresis, 1998
- Selective Determination of Cytochromecby Capillary Zone Electrophoresis with Amperometric Detection at a L-Cysteine-Modified Gold Microdisk Array ElectrodeAnalytical Letters, 1997
- Simultaneous joule heating and potential cycling of cylindrical microelectrodesAnalytica Chimica Acta, 1995
- Improved method for end-column amperometric detection for capillary electrophoresisAnalytical Chemistry, 1993