Near-infrared acetylene sensor system using off-axis integrated-cavity output spectroscopy and two measurement schemes
Authors:
- 21 September 2018
- journal article
- research article
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (20) , 26205-26216
Abstract
For highly sensitive and accurate acetylene (C2H2) detection, a near-infrared (NIR) off-axis integrated-cavity output spectroscopy (OA-ICOS) sensor system based on an ultra-compact cage-based absorption cell was proposed. The absorption cell with dimensions of 10 cm × 8 cm × 6 cm realized a dense-pattern and an easily-aligned stable optical system. The OA-ICOS sensor system employed a 6cm-long optical cavity that was formed by two mirrors with a reflectivity of 99.35% and provided an effective absorption path length of ∼9.28 m. The performance of the C2H2 sensor system based on two measurement schemes, i.e. laser direct absorption spectroscopy (LDAS) and wavelength modulation spectroscopy (WMS) is reported. A NIR distributed feedback (DFB) laser was employed for targeting a C2H2 absorption line at 6523.88 cm−1. An Allan deviation analysis yielded a detection sensitivity of 760 parts-per-billion in volume (ppbv) for an averaging time of 304 s using the LDAS-based OA-ICOS. A detection sensitivity of 85 ppbv for an averaging time of 250 s was obtained using the WMS-based OA-ICOS, which was further improved by a factor of ~9 compared to the result obtained with the LDAS method. The proposed sensor system has the advantages of reduced size and cost with acceptable detection sensitivity, which is suitable for applications in trace gas sensing in harsh environments and weight-limited balloon-embedded observations.Keywords
Funding Information
- Industrial Innovation Program of Jilin Province, China (2017C027)
- Key Science and Technology R&D program of Jilin Province, China (20180201046GX)
- National Key R&D Program of China (2016YFC0303902, 2016YFD0700101, 2017YFB0405300)
- National Natural Science Foundation of China (NSFC) (61627823, 61775079)
- National Science Foundation (NSF) (R4925U)
- Welch Foundation (R4925U)
This publication has 21 references indexed in Scilit:
- Cavity-Enhanced Near-Infrared Laser Absorption Spectrometer for the Measurement of Acetonitrile in BreathAnalytical Chemistry, 2015
- A mid-infrared absorption diagnostic for acetylene detectionApplied Physics B, 2015
- Three mirror off axis integrated cavity output spectroscopy for the detection of ethylene using a quantum cascade laserSensors and Actuators B: Chemical, 2014
- Acetylene detection based on diode laser QEPAS: combined wavelength and residual amplitude modulationApplied Physics B, 2012
- Self-broadening coefficients and positions of acetylene around 1.533μm studied by high-resolution diode laser absorption spectrometryJournal of Quantitative Spectroscopy and Radiative Transfer, 2010
- Wavelength modulated off-axis integrated cavity output spectroscopy in the near infraredApplied Physics B, 2006
- Optical–feedback cavity–enhanced absorption: a compact spectrometer for real–time measurement of atmospheric methaneApplied Physics B, 2006
- Combining a difference-frequency source with an off-axis high-finesse cavity for trace-gas monitoring around 3 µmOptics Express, 2006
- Off-axis continuous-wave cavity-enhanced absorption spectroscopy of narrow-band and broadband absorbers using red diode lasersApplied Physics B, 2002
- Sensitive absorption measurements in the near-infrared region using off-axis integrated-cavity-output spectroscopyApplied Physics B, 2002