Abstract
A compact in-line interferometer is proposed and experimentally demonstrated for gas refractive index (GRI) measurement. The sensor comprises a tapered four-core fiber (TFCF) sandwiched between two single-mode fibers (SMFs), forming an in-line SMF–TFCF–SMF structure. The fiber taper acts as a bridge between the external GRI variation and the multimode interference within the TFCF segment. A high sensitivity of 1280.94 dB/refractive index unit is obtained in GRI measurement around 1.0. Temperature change only shifts the interference wavelength, and the cross-sensitivity of temperature can be ignored by intensity demodulation. The proposed gas refractometer, with its improved performance, can be a good candidate for chemical sensing or bio-sensing.
Funding Information
  • National Natural Science Foundation of China (NSFC) (61327012, 61605159, 61735014)
  • National Key Research and Development Plan, Key Strategic Advanced Electronic Materials (2017YFB0405502)
  • National Science and Technology Project, Large Oil and Gas Field and Coal Bed Gas Development Project (2016ZX05019007-01)
  • Northwest University Graduate Innovation and Creativity Funds (YZZ17088)

This publication has 41 references indexed in Scilit: