Abstract
Angle-resolved x-ray photoelectron spectroscopy (XPS) has been used to study the short-range order (SRO) in epitaxial layers (1–73 monolayers) of Ag and Au on Ni(100). The basis for this technique is the enhancement of core-level intensities which occur along nearest-neighbor axes in the lattice due to photoelectron forward scattering. The XPS results indicate the Ag and Au films are very different in structure. Ag films exhibit conventional (111) surfaces, whereas the Au films have a SRO closely resembling a (100) surface. Surprisingly, the Au films exhibit a clear, sharp, hexagonal low-energy electron diffraction (LEED) pattern indistinguishable from the Ag(111) LEED pattern at beam energies below 200 eV. Above 300 eV, the Au films exhibit additional spots, which would seem to imply that deeper Au layers have a (100) structure and are in registry with the Ni(100). However, such registry would require an unrealistically large compression of the Au. Therefore, this structure cannot be considered fully ‘‘solved.’’ However, it is clear the Au films are (100)-like in the bulk and likely that they have a hexagonal monolayer at the surface. This is somewhat like the pure Au(100) surface. Thus the long-range order of the surface monolayer dominates in LEED below 200 eV, while the SRO of the bulk dominates in XPS. These results demonstrate the importance of XPS forward scattering as a probe of SRO in epitaxial films.