In‐line coupling of a reversed‐phase column to cope with limited chemoselectivity of a quinine carbamate‐based anion‐exchange type chiral stationary phase
- 30 May 2008
- journal article
- research article
- Published by Wiley in Journal of Separation Science
- Vol. 31 (10) , 1702-1711
Abstract
A chiral stationary phase based on tert‐butylcarbamoyl quinine has shown remarkable enantiomer separation capability for the thyroid hormone thyroxine (T4) and its structural analogue triiodothyronine (T3) employing hydroorganic buffered mobile phases (typical RP conditions). To overcome the problem of a somehow limited chemoselectivity for the critical peak pair between adjacent L‐thyroxine (L‐T4) and D‐thyroxine (D‐T4) peaks on the chiral anion‐exchanger CSP when all four compounds need to be analysed simultaneously like in impurity profiling of L‐T4 drug products, an RP column (Gemini C18) was serially coupled with the chiral anion‐exchanger column to add a hydrophobic selectivity increment and to improve thereby the critical resolution between L‐T3 and D‐T4. Various parameters such as organic modifier content, pH, buffer concentration and type, type of achiral column as well as sequence of achiral and chiral column have been investigated with individual and tandem columns. With the optimized conditions and use of the tandem column a significantly improved separation, as compared to the chiral anion‐exchanger column alone, with a critical resolution as high as 3.7 and an almost equal band spacing of the four components of the test mixture could be obtained. The sequence of the columns (achiral–chiral or chiral–achiral) had no significant effect on the separation performance.Keywords
This publication has 21 references indexed in Scilit:
- Enantioselective HPLC of potentially CNS‐active acidic amino acids with a cinchona carbamate based chiral stationary phaseChirality, 2008
- Stationary phase optimized selectivity liquid chromatography: Basic possibilities of serially connected columns using the “PRISMA” principleJournal of Chromatography A, 2007
- Comprehensive analysis of branched aliphatic d-amino acids in mammals using an integrated multi-loop two-dimensional column-switching high-performance liquid chromatographic system combining reversed-phase and enantioselective columnsJournal of Chromatography A, 2007
- Impact of amines as co-modifiers on the enantioseparation of various amino acid derivatives on a tert-butyl carbamoylated quinine-based chiral stationary phaseTalanta, 2006
- HPLC enantiomer separation of a chiral 1,4-dihydropyridine monocarboxylic acidJournal of Pharmaceutical and Biomedical Analysis, 2004
- Quinine and quinidine derivatives as chiral selectors I. Brush type chiral stationary phases for high-performance liquid chromatography based on cinchonan carbamates and their application as chiral anion exchangersJournal of Chromatography A, 1996
- Determination of the stereochemical composition of the major metabolites of verapamil in dog urine with enantioselective liquid chromatographic techniquesJournal of Chromatography B: Biomedical Sciences and Applications, 1995
- Two-dimensional high-performance liquid chromatographic system for the determination of enantiomeric excess in complex amino acid mixturesJournal of Chromatography A, 1993
- Factors controlling the level and determination of D-amino acids in the urine and plasma of laboratory rodentsAmino Acids, 1993
- VARIOUS EFFECTS OF THYROXINE ANALOGUES ON THE HEART AND SERUM CHOLESTEROL IN THE RATJournal of Endocrinology, 1960