Influence of the Modeling Depth and Voltage Level on the AC Losses in Parallel Conductors of a Permanent Magnet Synchronous Machine
- 2 February 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
Abstract
Analysis of AC effects, such as skin and proximity effect as well as the circulating currents and corresponding losses are usually done by finite element analysis (FEA), while mostly only a single slot is considered, neglecting the influence of neighboring phases on the flux density of the stator iron and thus the resulting slot leakage flux. As the simulation of single stranded FE models is computationally very demanding and time consuming, this work compares different levels of detail of 2D FE models and investi-gates the impact of the modelling depth on the resulting copper loss to find a computation time optimized modeling setup. Moreover, the potential increase of AC-losses is assessed for two machines that are identical except for the stator winding, so that one and the same machine is investigated at two different voltage levels, namely 400 V and 800 V. The reference machine is a 160 kW nominal power and 9000 rpm maximum speed perma-nent magnet synchronous machine. Since the magnetic circuit has to remain constant, both designs share the same overall winding scheme and total number of strands within a slot but differ in the number of parallel and serial connected strands.Keywords
This publication has 27 references indexed in Scilit:
- Efficient Finite-Element Computation of Circulating Currents in Thin Parallel StrandsIEEE Transactions on Magnetics, 2015
- Analytical model for predicting AC losses in form-wound machine windings due to stator current interactions2015
- Influence of parallel wire placement on the AC copper losses in electrical machines2015
- Analytical 2-D slot model for predicting AC losses in bar-wound machine windings due to armature reaction2014
- Analysis of the proximity and skin effects on copper loss in a stator coreArchives of Electrical Engineering, 2014
- Scaling of AC copper loss in thermal modeling of electrical machines2012
- Stranded wire with uninsulated strands as a low-cost alternative to litz wire2004
- Cost-constrained selection of strand diameter and number in a litz-wire transformer windingIEEE Transactions on Power Electronics, 2001
- Improved analytical modeling of conductive losses in magnetic componentsIEEE Transactions on Power Electronics, 1994
- Effects of eddy currents in transformer windingsProceedings of the Institution of Electrical Engineers, 1966