Abstract
Analysis of AC effects, such as skin and proximity effect as well as the circulating currents and corresponding losses are usually done by finite element analysis (FEA), while mostly only a single slot is considered, neglecting the influence of neighboring phases on the flux density of the stator iron and thus the resulting slot leakage flux. As the simulation of single stranded FE models is computationally very demanding and time consuming, this work compares different levels of detail of 2D FE models and investi-gates the impact of the modelling depth on the resulting copper loss to find a computation time optimized modeling setup. Moreover, the potential increase of AC-losses is assessed for two machines that are identical except for the stator winding, so that one and the same machine is investigated at two different voltage levels, namely 400 V and 800 V. The reference machine is a 160 kW nominal power and 9000 rpm maximum speed perma-nent magnet synchronous machine. Since the magnetic circuit has to remain constant, both designs share the same overall winding scheme and total number of strands within a slot but differ in the number of parallel and serial connected strands.