A bone composition model for Monte Carlo x‐ray transport simulations
Authors:
- Hu ZhouHZHu Zhou
- Paul J. KeallPKPaul J. Keall
- Edward E. GravesEGEdward E. Graves
- 25 February 2009
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 36 (3) , 1008-1018
Abstract
In the megavoltage energy range although the mass attenuation coefficients of different bones do not vary by more than 10%, it has been estimated that a simple tissue model containing a single‐bone composition could cause errors of up to 10% in the calculated dose distribution. In the kilovoltage energy range, the variation in mass attenuation coefficients of the bones is several times greater, and the expected error from applying this type of model could be as high as several hundred percent. Based on the observation that the calcium and phosphorus compositions of bones are strongly correlated with the bone density, the authors propose an analytical formulation of bone composition for Monte Carlo computations. Elemental compositions and densities of homogeneous adult human bones from the literature were used as references, from which the calcium and phosphorus compositions were fitted as polynomial functions of bone density and assigned to model bones together with the averaged compositions of other elements. To test this model using the Monte Carlo package DOSXYZnrc, a series of discrete model bones was generated from this formula and the radiation‐tissue interaction cross‐section data were calculated. The total energy released per unit mass of primary photons (terma) and Monte Carlo calculations performed using this model and the single‐bone model were compared, which demonstrated that at kilovoltage energies the discrepancy could be more than 100% in bony dose and 30% in soft tissue dose. Percentage terma computed with the model agrees with that calculated on the published compositions to within 2.2% for kV spectra and 1.5% for MV spectra studied. This new bone model for Monte Carlo dose calculation may be of particular importance for dosimetry of kilovoltage radiation beams as well as for dosimetry of pediatric or animal subjects whose bone composition may differ substantially from that of adult human bones.Keywords
This publication has 32 references indexed in Scilit:
- Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planningMedical Physics, 2007
- Conversion of CT numbers into tissue parameters for Monte Carlo dose calculations: a multi-centre studyPhysics in Medicine & Biology, 2007
- Clinical comparison of head and neck and prostate IMRT plans using absorbed dose to medium and absorbed dose to waterPhysics in Medicine & Biology, 2006
- Sensitivity study for CT image use in Monte Carlo treatment planningPhysics in Medicine & Biology, 2005
- Clinical use of a commercial Monte Carlo treatment planning system for electron beamsPhysics in Medicine & Biology, 2005
- Reply to `Comments on `Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations' 'Physics in Medicine & Biology, 2000
- Clinical implementation of a Monte Carlo treatment planning systemMedical Physics, 1999
- The calibration of CT Hounsfield units for radiotherapy treatment planningPhysics in Medicine & Biology, 1996
- Average soft-tissue and bone models for use in radiation dosimetryBritish Journal of Radiology, 1987
- Bone models for use in radiotherapy dosimetryBritish Journal of Radiology, 1982